Installation Preparation – Hot Water Supply

Installation Preparation – Hot Water Supply

Prepare Hot Water Supply

Hot Water Line

The line may enter from either side, rear or floor within the shaded area shown in Figure F.

The line may pass through the same hole as the electrical cable and drain hose, or cut an additional 1-1/2" diameter hole to accommodate the water line. If a power cord with plug is used, the water line must not pass through the power cord hole.

Prepare Hot Water Supply CAUTION

The hot water supply line pressure must be at least 20 PSI. Lower pressures could cause the water valve to leak and cause water damage.

PRECAUCIÓN

La línea de presión del suministro de agua caliente debe ser al menos 20 PSI. Presiones inferiores podrían causar que la válvula del agua gotee y causar daños por agua.

 

1-1/2" Dia.

4"

5" 4"

 

5"

 

Shut-off Hole

 

 

Hot

Valve

 

 

 

 

 

 

2"

 

6"

 

 

 

 

From

19" From Wall

 

Cabinet

 

Cabinet FaceManual background

Figure F

2" From Floor

Water Line Connection

Turn off the water supply.

Install a hand shut-off valve in an accessible location, such as under the sink. (Optional, but strongly recommended and may be required by local codes.)

The water connection is on the left side of the dishwasher. Install the hot water inlet line, using 3/8" or larger copper tubing. Route the line as shown in Figure F and extend forward at least 19" from rear wall.

Adjust the water heater to deliver water between

120°F and 150°F.

Flush water line to clean out debris. Use a bucket to catch water and debris.

The hot water supply line pressure must be between 20 and 120 PSI.