Sanitizing the Reverse Osmosis System

Sanitize upon installation of the Reverse Osmosis system and after servicing inner parts, including replacement of prefilter, postfilter and the Reverse Osmosis cartridge. Be sure you clean your hands with anti-bacterial soap before handling inner parts of the system.

CAUTION: Before sanitizing, be sure to remove all cartridges as follows. Chlorine will destroy the Reverse Osmosis cartridge.

 

Be sure the water supply valve to the Reverse

1

 

Osmosis system is turned off, and the RO

 

water faucet and storage tank are open. Allow

 

the system to drain completely (this takes

 

several minutes).

 

Pull the Reverse Osmosis system out away

2

 

from cabinet. Leave tubing connected.

 

Place a dry towel under the Reverse Osmosis

 

unit. Using pliers remove the lock washer,

 

pull the u-pin clip and remove the Reverse

 

Osmosis housing inlet cover. Save the lock

 

washer for final assembly.

 

Remove (using pliers) the Reverse Osmosis

3

 

cartridge from the housing. Place the

 

cartridge in a clean plastic bag.

 

Replace the inlet cover and u-pin, making

4

 

sure the o-ring is in place.

 

Remove the POSTFILTER sump by turning

5

 

it to the left using the sump wrench tool

 

provided. Be careful, the sump is full of water.

 

Remove the cartridge from the sump and

 

place in a clean plastic bag. Make sure the

 

o-ring is seated in the top of the sump. With

 

the o-ring seal in position, replace the sump

 

and tighten securely by hand.

 

Remove the PREFILTER sump and

6

 

cartridge. Place this cartridge in a clean

plastic bag.

7 Fill the prefilter sump with cold water to about 1″ from the o-ring. Add 1 ounce (2 tablespoons) of ordinary 5.25% household chlorine bleach and mix into the water. Do

not add chlorine first. Concentrated chlorine may damage plastic.

8 Carefully replace the sump (make sure the o-ring valve seal is in place) on the prefilter head and tighten securely by hand.

9 Close the RO water faucet. Open the water supply valve (turn counterclockwise) to the Reverse Osmosis system. Allow system to fill for one minute.

10 Open the RO water faucet and allow water to flow for 10 minutes through the Reverse Osmosis system. Close RO water faucet for one minute and then open faucet and allow water to flow (approximately 10 minutes) until bleach odor is gone.

11 Turn off the water supply valve (turn clockwise) to the Reverse Osmosis system. After water flow stops, leave the RO water faucet open.

12 Be sure hands have been cleaned with anti-bacterial soap. Repeat steps 1–6 and 8; however, reinstall the cartridges instead of removing them.

NOTE: The Reverse Osmosis cartridge o-ring end is notched and may need to be rotated during reinstallation for proper fit.

13 After installing/reinstalling cartridges, close RO water faucet and open water supply valve (turn counterclockwise). Check for leaks.

Safety Instructions

Operating Instructions

Troubleshooting Tips

Reverse Osmosis housing

 

U-pin

 

Lock washer

Automatic

Reverse Osmosis cartridge

shutoff

 

assembly

 

Prefilter

 

cartridge

O-ring end

 

O-ring

Postfilter

inside

cartridge

sump

Sump Wrench

 

Sump

Inlet cover

Sump

 

Loosen

Turn sump this way to remove

9

 

Customer Service

Page 9
Image 9
GE 215c1002p004-4 owner manual Sanitizing the Reverse Osmosis System

215c1002p004-4 specifications

The GE 215C1002P004-4 is a high-performance electronic device that has gained prominence in various industrial and commercial applications. This component is part of General Electric's line of advanced technologies, reflecting the company's ongoing commitment to innovation and reliability.

One of the key features of the GE 215C1002P004-4 is its robust design, which allows it to operate efficiently in demanding environments. The device is engineered to withstand extreme temperatures and harsh conditions, ensuring longevity and dependable performance. This ruggedness makes it suitable for use in sectors such as manufacturing, aerospace, and energy.

In terms of technology, the GE 215C1002P004-4 boasts cutting-edge features that enhance its functionality. It incorporates advanced circuitry that enables precise control and monitoring capabilities. This is crucial for applications where accuracy is paramount, such as in industrial automation systems. The device also supports various communication protocols, making it versatile and compatible with a wide range of existing systems.

Another significant characteristic of the GE 215C1002P004-4 is its energy efficiency. As industries worldwide strive to reduce their carbon footprint and operational costs, the energy-efficient design of this device makes it an attractive option. It optimizes power consumption while maintaining high performance levels, aligning with modern sustainability goals.

The user interface of the GE 215C1002P004-4 is designed to be intuitive, facilitating easy operation and monitoring. This ease of use is crucial for technicians and operators who need to access real-time data and diagnostics to ensure optimal performance and quick troubleshooting.

Furthermore, the GE 215C1002P004-4 is compliant with various industry standards, ensuring that it meets rigorous safety and quality requirements. This compliance reinforces its reliability and bolsters customer confidence in its performance.

In conclusion, the GE 215C1002P004-4 is a versatile and efficient electronic device that stands out due to its rugged design, advanced technology, energy efficiency, and user-friendly interface. As industries continue to evolve, components like the GE 215C1002P004-4 play a vital role in driving innovation and improving operational efficiency across various sectors. Whether used in automation, control systems, or other applications, it exemplifies the quality and reliability that General Electric is known for.