INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT: Save these instructions for the local electrical inspector’s use.

IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.

NOTE TO INSTALLER: Leave these instructions with the appliance after installation is completed.

NOTE TO CONSUMER: Keep this Use and Care Guide and Installation Instructions for future use.

NOTE: This appliance must be properly grounded.

TOOLS YOU WILL NEED

Large blade screwdriver

Channel lock pliers or small ratchet wrench with 3/16-inch socket (for leveling range)

1/4-inch hex head nutdriver

ELECTRICAL REQUIREMENTS

CAUTION, FOR PERSONAL SAFETY:

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

REMOVE HOUSE FUSE OR OPEN CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or time delay fuse, as noted on the rating plate.

Wiring must conform to National Electric Codes.

If the electric service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used.

34

STEP 1

PREPARE THE OPENING

112 inch spacing is recommended from the range to adjacent vertical walls above cooktop surface.

Allow 30 inches minimum clearance between surface units and bottom of unprotected wood or metal top cabinet, and 15 inches minimum between countertop and adjacent cabinet bottom.

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a min. of 5 inches beyond the bottom of the cabinets. Make sure the wall covering, countertops and cabinets around the range can withstand heat generated by the range, oven or cooktop up to 200°F.

NOT LESS THAN

WIDTH OF RANGE

 

 

 

 

 

HOOD

 

 

 

 

 

5MIN.

30

 

 

 

 

 

MIN. 15

 

 

 

 

 

MIN.

 

 

 

 

 

 

 

 

 

LOCATE

 

 

 

 

 

OUTLET BOX

WALL

 

 

 

 

WITHIN EITHER

 

 

 

 

SHADED AREA

 

112

 

 

 

 

 

MIN.

 

 

 

 

INSTALL

 

 

 

 

 

OUTLET BOX

 

 

 

 

ON EITHER

WALL

C OF RANGE

 

SIDE OF C

 

L

 

 

 

L

 

712

 

 

 

OUTLET

7

7

1

1458

 

2

 

 

BOX

312

 

 

5

 

 

 

 

 

BEFORE YOU BEGINTOOLS YOU WILL NEEDELECTRICAL REQUIREMENTS 214

CORD STEP 1 FLOOR

Anti-Tip Bracket Manual background (install in either rear corner)