GE 4164D2966P234, 49-8723 warranty Wire Conduit Installation, Note Aluminum Wiring

Models: 4164D2966P234 49-8723

1 44
Download 44 pages 27.07 Kb
Page 37
Image 37
STEP 6

STEP 6

3 WIRE CONDUIT INSTALLATION

Remove the 3 screws from the connector block. Insert bare wires between the connector block terminals and movable nuts. Tighten screws securely. Do not remove ground strap connection.

 

SCREW

 

CONNECTOR

 

BLOCK

 

TERMINAL

BARE

 

WIRE

 

MOVABLE

FLEXIBLE

NUT

CABLE

CONNECTOR

BLOCK

BARE

WIRE TIPS

BRACKET NOTE: ALUMINUM WIRING

CONDUIT

WARNING: CONNECTOR BLOCK IS APPROVED FOR COPPER WIRE CONNECTION ONLY. IF ALUMINUM WIRE IS USED, SEE NOTE BELOW.

NOTE: ALUMINUM WIRING

A.Do not connect Aluminum wire to connector block. Use copper building wire rated for the correct amperage and voltage to make 3 (three) 3 inch copper jumper wires. Connect wire as per Step 6 or 7 depending on number of wires.

B.Splice copper wires to aluminum wiring using special connector terminals designed and UL approved for joining copper to aluminum and follow the connector manufacturers recommended procedure closely.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.

STEP 7

4 WIRE CONDUIT INSTALLATION

Remove the 3 screws from the connector block. Remove the grounding strap from the connector block middle location and the screw connecting it to the frame of the range. Insert bare wires between the connector block terminals and movable nuts. Tighten screws securely. Attach ground wire to the frame of the range.

 

SCREW

 

CONNECTOR

 

BLOCK

 

TERMINAL

BARE

 

WIRE

 

MOVABLE

FLEXIBLE

NUT

CABLE

CONNECTOR

 

BLOCK

BARE

 

 

WIRE TIPS

BRACKET

 

STEP 7 CONDUIT

WARNING: CONNECTOR BLOCK IS APPROVED FOR COPPER WIRE CONNECTION ONLY. IF ALUMINUM WIRE IS USED, SEE NOTE BELOW.

NOTE: ALUMINUM WIRING

A.Do not connect Aluminum wire to connector block. Use copper building wire rated for the correct amperage and voltage to make 3 (three) 3 inch copper jumper wires. Connect wire as per Step 6 or 7 depending on number of wires.

B.Splice copper wires to aluminum wiring using special connector terminals designed and UL approved for joining copper to aluminum and follow the connector manufacturers recommended procedure closely.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.

(continued next page)

37

Page 37
Image 37
GE 4164D2966P234, 49-8723 warranty Wire Conduit Installation, Note Aluminum Wiring