Safety Instructions

About the controls on the air conditioner—models with touch pads.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

The display always shows the room

Light indicates the unit

is in the temperature or

temperature except when setting the

delay time Set mode.

Set temperature or the Delay timer.

 

Operating

Instructions

Light indicates Circulaire is on.

Light indicates the delay timer is set.

Delay 1–24hr

Delay timer Decrease Mode select

Fan speed

Decrease

Temperature

set Increase

and Decrease

 

 

Delay

 

M

ode

 

o

 

Aut

 

 

Fan

 

-

F

a

n

 

a

 

 

n

F

 

 

+

Temp

Power

Delay timer Increase

Circulaire

Auto Fan on/off

Fan speed Increase

Unit power on/off

Air Conditioner Controls

Remote Control

Controls

Care and Cleaning

Installation Instructions

Troubleshooting Tips

The air conditioner controls are located behind the control panel door. Press to open and close the door.

NOTE: The remote control will work with the control panel door open or closed.

Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.

NOTE: The display will change to show the room temperature after settings have been made. To recall the Set temperature, press the Temp Increase or Decrease pads.

Temp Increase /Decrease Pads

Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

Delay Timer Increase (+) /Decrease (–)

Pads

Mode Pad

Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

Delay Pads

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay 1–24hrpad on the unit or

the pad on the remote control. Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control will set the timer in

1-hour intervals. The Set light will turn on while setting.

To review the remaining time on the Delay 1–24hrtimer, press the Delay 1–24hrpad on the unit or thepad on the remote control. Use the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control to set a new time if desired.

Support

Each touch of the Increase / Decrease

To cancel the timer, press the Delay 1–24hr pad

pads on the unit or the Increase + / Decrease

until the light on the Delay 1–24hrpad goes off.

pads on the remote control will set the delay

CIRCULAIRE Pad

time when using the Delay 1–24hrtimer ( ).

Turn on to provide continuous side-to-side

The Set light will turn on while setting.

air circulation.

 

Consumer

Fan Speed Pads

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

4

For fixed side-to-side air direction, turn on until the desired air direction is obtained, then turn it off.

Page 4
Image 4
GE AEM25*, AEH25*, AEM18*, AEH18* installation instructions Safety Instructions, Care and Cleaning, Support, Consumer

AEH18*, AEM18*, AEH25*, AEM25* specifications

General Electric (GE) has made significant strides in the evolution of its gas turbine technology with the introduction of the AEM18*, AEM25*, AEH25*, and AEH18* series. These models are engineered to meet the growing demands for efficient, reliable, and environmentally responsible energy generation.

The AEM18* and AEM25* models focus on advanced aerodynamics and materials science to deliver high efficiency and performance. These turbines utilize a state-of-the-art combustion system that enables low emissions operation while maintaining operational flexibility. The AEM series is renowned for its capabilities in combined cycle applications, offering a high power-to-weight ratio which enhances overall system efficiency.

The AEH25* and AEH18* models build upon the advanced technology established in the AEM series but introduce enhancements aimed at heavy-duty and industrial applications. With innovative design modifications, including improved rotor dynamics and robust cooling techniques, these turbines achieve excellent reliability and availability. The AEH series is designed with high operational flexibility, capable of handling high load variations while providing consistent performance.

All four turbine models share GE's commitment to utilizing advanced digital technologies, including the Predix platform, which harnesses the power of analytics. This technology allows operators to monitor performance in real time, predict maintenance needs, and optimize operational parameters, resulting in reduced downtime and improved efficiency.

In terms of characteristics, the AEM and AEH series turbines are characterized by their modular design, which simplifies installation and maintenance processes. This design allows for easier upgrades and retrofits, ensuring that customers can adapt their systems to future technological advancements.

The environmental impact of these gas turbines cannot be understated. Both the AEM and AEH series are designed to meet rigorous emissions standards, showcasing GE's commitment to sustainability. With reduced greenhouse gas emissions and the capacity to integrate with renewable energy sources, these turbines serve as a key component in the transition to cleaner energy systems.

In summary, the GE AEM18*, AEM25*, AEH25*, and AEH18* turbines represent a culmination of innovative engineering, advanced technology, and a focus on environmental sustainability, making them suitable choices for a variety of energy generation applications in today's dynamic energy landscape.