Read completely, then follow step-by-step.

Safety

1

Window Requirements

■ These instructions are for a standard double-

hung window. You will need to modify them

for other types of windows.

■ The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.

■ All supporting parts must be secured to firm wood, masonry or metal.

■ The electrical outlet must be within reach of the power cord.

16″ min.

27″ to 39″

(with accordion panels)

237⁄8″ min.

(without accordion panels)

Instructions Operating Instructions

2

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and

 

will keep it from draining properly. To adjust

 

for this, attach a piece of wood to the stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

1/2″ higher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storm window

 

 

 

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOOD PIECES—

WIDTH: 2″

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Installation Instructions Troubleshooting Tips Consumer Support

9

Page 9
Image 9
GE AGE12 operating instructions Safety, Storm Window Requirements