GE AJCM 08 ACD Installation Instructions, Measure,Panels Cut And Install Filler

Models: AJCM 08 ACD

1 24
Download 24 pages 44.67 Kb
Page 19
Image 19
6 MEASURE,PANELS CUT AND INSTALL FILLER

Installation Instructions

6 MEASURE,PANELS CUT AND INSTALL FILLER

AMeasure from the edge of the panel marks (see Prepare the Window) to the inside of the window track on each side (A and B).

Sill

Window track

Outside

13381338

ABMark the A and B measurements on each side Width of the air Manual background B

 

 

 

Inside

conditioner

 

 

 

Left side

Right side

(panel marks)

 

BMark the A and B measurements on each side

of the filler panel board. Cut the panels and discard the center piece. Note position of the notches.

B

A

Right

Left side

side

(holes areontheright)

onare(holesthe left)

 

Filler Panels

 

Cut panels

 

and discard

 

center piece

CPut together the panel assemblies. Remove the paper backing from the case-side gasket and attach it to the angle. Push a pencil point through the gaskets to locate the holes in the angles.

Gasket

Angle

Angle

Type C

(painted

screws)

GasketPanel

Tab

DInstall the panels in the window. Place the spring clips 3from the top and the bottom. Squeeze and push the clips to fit in the window track and the tab into the sill support.

Manual background 3

Hook the tab into the sill support

19

Page 19
Image 19
GE AJCM 08 ACD installation instructions Installation Instructions, Measure,Panels Cut And Install Filler