B. Installing Vent Components

After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly.

NOTE: The SL-350TRS-C and SL-350TRS-C LP are built with the air shutter set for top vented configurations. If venting out the rear of the unit adjust the air shutter per the table in Step 10.

Venting Out the Rear Vent (See Figure 21)

Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end. Remove the insulation inside the 5” collar. Follow the vent configuration tables accordingly.

Remove the 5” diameter heat shield from the 5” diameter collar by sliding it out.

!WARNING: THE TOP HEAT SHIELD (INSIDE THE FIREBOX) MUST REMAIN ATTACHED IF THE VENT SYSTEM IS ATTACHED TO THE REAR STARTING COLLARS. SEE FIGURE 21.

Venting Out the Top Vent

Remove the top vent collar seal cap by cutting the strap at each end. Remove the insulation inside BOTH the 4” diameter and 6 5/8” diameter collars. (See Figure 21).

Remove the 4” diameter heat shield from the 4” diameter collar by sliding it out.

You have to take the glass off for positioning the logs when the unit is finally installed in place and finished around it. Attach vent system to the top starting collars.

!WARNING: THE REAR VENT COLLAR SEAL CAP MUST REMAIN ATTACHED TO THE REAR

VENT COLLARS IF THE VENT SYSTEM ISATTACHED TO THE TOP STARTING COLLARS. SEE FIGURE 21.

WARNING: FAILURE TO REMOVE INSULATION

!IN THE SET OF COLLARS YOU ARE USING COULD NEGATIVELY AFFECT APPLIANCE PERFORMANCE.

!WARNING: YOU MUST LEAVE THE INSULA- TION IN PLACE IN THE SET OF COLLARS YOU ARE NOT USING. FAILURE TO DO THIS COULD CAUSE A FIRE.

Insert screwdriver

Venting

 

 

Venting

or similar object

Out Rear

 

 

Out Top

here to remove cap.

 

 

 

 

SEAL

SEAL

INSULATION,

 

 

CAP

DISCARD

 

 

CAP

 

 

 

BOTH

 

 

 

 

 

 

 

 

PIECES

 

HEAT

 

 

 

 

SHIELD

 

 

 

 

DISCARD

 

 

HEAT

 

 

SHIELD

 

INSULATION

 

 

 

CUT HERE

Figure 21.

DVP Series Venting Only:

1. Attaching the Venting to the Appliance

Refer to Cinch Pipe and Termination Cap installation in- structions.

WARNING: ENSURE THAT THE FIBERGLASS

!GASKET SUPPLIED WITH THE APPLIANCE SEALS BETWEEN THE FIRST VENT COMPONENT AND THE OUTER APPLIANCE WRAP.

If the installation is for a termination cap attached directly to the appliance, skip to the sections, Install Firestops and Vent Termination.

2. Continue Adding Vent Components

Refer to Cinch Pipe and Termination Cap installation in- structions.

Continue adding vent components, locking each succeed- ing component into place.

Ensure that each succeeding vent component is secure- ly fitted and locked into the preceding component in the vent system.

90° elbows may be installed and rotated to any point around the preceding component’s vertical axis. If an el- bow does not end up in a locked position with the pre- ceding component, attach with a minimum of two (2) sheet metal screws.

3. Install Support Brackets

Refer to Cinch Pipe and Termination Cap installation in- structions.

Go to Step 4 Install Firestops.

32

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Page 32
Image 32
Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual DVP Series Venting Only, Go to Install Firestops