V

 

H

 

1' MIN. (305mm)

2'

MAX. (610mm)

 

2' MIN. (610mm)

4'

MAX. (1.22m)

 

3' MIN. (914mm)

6'

MAX. (1.86m)

 

4' MIN. (1.22m)

8'

MAX. (2.4m)

 

V+H=40' MAX. (12.4m)

 

 

H = 8' MAX. (2.4m)

 

 

 

 

 

 

V

Use DVP-Series

 

components only.

H

Figure 12. Venting with One 90° Elbow

H

Use SL D-Series components only.

VENTING WITH ONE (1) 90o ELBOW

NATURAL GAS

 

MODEL: SL-350TRS-C MODELS: SL-550TRS-D, SL-750TRS-D

V (MIN.)

H (MAX.)

 

H (MAX.)

90o Elbow on Top

2.5 FT (762mm)

 

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

 

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

 

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

 

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

 

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

 

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

 

 

 

 

VENTING WITH ONE (1) 90o ELBOW

PROPANE

MODELS: SL-350TRS-C, SL-550TRS-D, SL-750TRS-D

V (MIN.)

H (MAX.)

 

90o Elbow on Top

NOTALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

 

 

 

V

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installa- tion (see Figure 9).

Figure 13. Venting with One 90° Elbow

24

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Page 24
Image 24
Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual Use DVP-Series Components only