Heat & Glo LifeStyle SL-750TRS-IPI-D Use SL D-Seriescomponents only, Venting with three 90 elbows

Models: SL-750TRS-IPI-D

1 45
Download 45 pages 57.97 Kb
Page 30
Image 30
MODEL SL-750TRS-D

VENTING WITH THREE (3) 90o ELBOWS

NATURAL GAS

 

MODEL SL-550TRS-D

MODEL SL-750TRS-D

V (MIN.)

H + H1 (MAX.)

H + H1 (MAX.)

90o Elbow on Top

2 FT (610mm)

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

16 FT (4.8m)

H + H1 MAX. = 16 FT (4.8m)

V + V1 + H + H1

MAX. = 40 FT (12.2m)

 

 

 

 

VENTING WITH THREE (3) 90o ELBOWS

PROPANE

 

MODEL SL-550TRS-D

MODEL SL-750TRS-D

V (MIN.)

H + H1 (MAX.)

H + H1 (MAX.)

90o Elbow on Top

NOTALLOWED

NOTALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

16 FT (4.8m)

H + H1 MAX. = 16 FT (4.8m)

V + V1 + H + H1 MAX. = 40 FT (12.2m)

 

 

 

 

V1

V

H1

H

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installa- tion (see Figure 9).

Use SL D-Series components only.

Figure 19. Venting with three 90° elbows

30

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Page 30
Image 30
Heat & Glo LifeStyle SL-750TRS-IPI-D Use SL D-Seriescomponents only, Venting with three 90 elbows, Natural Gas, Propane