Heat & Glo LifeStyle SL-750TRS-IPI-D Use SL D-Seriescomponents only, Venting with three 90 elbows

Models: SL-750TRS-IPI-D

1 45
Download 45 pages 57.97 Kb
Page 29
Image 29
VENTING WITH THREE (3) 90o ELBOWS

VENTING WITH THREE (3) 90o ELBOWS

NATURAL GAS

 

 

MODEL: SL-350TRS-C

MODELS: SL-550TRS-D, SL-750TRS-D

V (MIN.)

 

H (MAX.)

H + H1 (MAX.)

 

 

H (MAX.)

H + H1 (MAX.)

 

 

 

90o Elbow on Top

 

2.5 FT (762mm) 4 FT (1.22m)

 

 

2 FT (610mm)

4 FT (1.22m)

1 FT (305mm)

 

3 FT (914mm)

6 FT (1.86m)

 

 

3 FT (914mm)

6 FT (1.86m)

2 FT (610mm)

 

4 FT (1.22m)

8 FT (2.48m)

 

 

4 FT (1.22m)

8 FT (2.48m)

3 FT (914mm)

 

6 FT (1.86m)

12 FT (3.72m)

 

 

6 FT (1.86m)

12 FT (3.72m)

4 FT (1.22m)

 

8 FT (2.48m)

16 FT (4.8m)

 

 

8 FT (2.48m)

16 FT (4.8m)

5 FT (1.52m)

 

16 FT (4.8m)

16 FT (4.8m)

 

 

16 FT (4.8m)

16 FT (4.8m)

 

 

V + H + V1 + H1 MAX. = 40 FT (12.2m)

 

 

 

 

 

 

 

 

 

VENTING WITH THREE (3) 90o ELBOWS

PROPANE

MODELS: SL-350TRS-C, SL-550TRS-D, SL-750TRS-D

V (MIN.)

 

H (MAX.)

H + H1 (MAX.)

 

90o Elbow on Top

 

NOT ALLOWED

NOT ALLOWED

1 FT (305mm)

 

2 FT (610mm)

4 FT (1.22m)

2 FT (610mm)

 

4 FT (1.22m)

8 FT (2.48m)

3 FT (914mm)

 

6 FT (1.86m)

12 FT (3.72m)

4 FT (1.22m)

 

8 FT (2.48m)

16 FT (4.8m)

5 FT (1.52m)

 

16 FT (4.8m)

16 FT (4.8m)

V + H + V1 + H1 MAX. = 40 FT (12.2m)

H

H1

V1

V

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installa- tion (see Figure 9).

Use SL D-Series components only.

Figure 18. Venting with three 90° elbows

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06