For Intermittent Pilot Ignition (IPI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the junction box. Maintain correct polarity when wiring the junc- tion box.

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Uninterrupted or continuous power is required at all times in IPI system EXCEPT when using battery back-up.

Incorrect wiring will override IPI safety lockout and may cause explosion.

Operation using Battery Power

This appliance has an optional battery operation. The sys- tem is fully functional with the use of two “D” size batteries without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate battery power (connect red to red, black to black). The appliance can be used as necessary. Once power (110 VAC) is re- stored, disconnect red and black wire leads to extend bat- tery life.

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the appliance is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the appliance ON/ OFF switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

 

 

 

 

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

 

 

 

 

I

 

 

 

 

 

 

S

 

 

 

 

TRANSFORMER

 

 

WHITE

 

 

 

3 VAC

 

 

 

HOT

NEUTRAL

 

 

 

ORANGE

 

 

 

GROUND TO

 

PLUG IN

 

FIREPLACE

 

 

 

 

 

CHASSIS

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

E

 

 

 

 

 

R

 

 

 

 

BATTERY PACK

 

 

 

JUMPER WIRE

 

 

 

 

 

 

(TO BROWN)

ORANGE

 

 

 

 

 

 

GREEN

THERMOSTAT

 

 

 

 

 

 

WIRE ASSEMBLY

 

 

 

 

VALVE

 

 

 

 

 

 

 

Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram

 

 

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

41

Page 41
Image 41
Heat & Glo LifeStyle SL-750TRS-IPI-D Operation using Battery Power, Intermittent Pilot Ignition IPI Wiring Diagram