Through-the-Wall Installation Instructions—Optional
The case may be installed through the wall in both existing and new construction.
Read completely, then follow
1IMPORTANT
All side louvers in the case must project on the outdoor side of the wall.
The room side of the case must project into the room at least 13⁄4″ from the finished wall.
2FINISH THE WALL OPENING
Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the outside of the building.
| Plaster line | |
Lintel angle (if required) |
| |
Caulking | Trim molding | |
(if desired) | ||
|
The case must be installed level from side-
A Remove the air conditioner from the case. |
For specific instruction, refer to the Window |
Installation Instructions. |
OUTSIDE
Air louvers (must project on the outdoor side of the wall)
INSIDE
Bottom rail
B Make certain that a wall receptacle is |
available close to the hole location or make |
arrangements to install a receptacle. |
CPlace the case in the wall opening and secure with 12 1″ long #10 wood screws.
NOTE: Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion.
Wood Filler and Caulking
(above and below the flashing)
Flashing (Drip rail)
4.5 cm (13/4″) min.
15