GEH-6639
2.6 CONVERTER SIZE SELECTION
Within the specified voltage field, the CS300 converter supplies the same rated direct current independently of the voltage itself. The increase of the output voltage causes an increasing in the transferred power, whereas inverters are devices with a typically constant transferred power (the supplied current decreases with the increasing of the output voltage).
As for the choice, therefore, the calculation is based on a common unit, the direct current of the intermediate circuit, which, as for the inverters, is not mentioned into the product instruction manual and has therefore to be calculated. Furthermore, the confrontation between the two foreseen functioning classes has to be homogeneous (IEC 146 class 1 and 2).
2.6.1 Output Rated Currents for the Two Functioning Classes
Converter | DC link current (Terminals C / D) | ||
IEC 146 Class 1 * | IEC 146 Class 2 ** | ||
| |||
|
|
| |
185 A | 150 A | ||
280 A | 225 A | ||
420 A | 340 A | ||
650 A | 540 A | ||
1050 A | 850 A | ||
1500 A | 1300 A |
cs060
* Continuous service
** Service with overload possibility of 150% for 60 seconds
14——————— INSTRUCTION MANUAL