Installation Instructions
C3. ADAPTING MICROWAVE BLOWER FOR RECIRCULATION
1Remove the back top center blower motor door retaining screw.
Blower Motor | Back of | |
Microwave | ||
|
Blower Door
Screw
2Open the blower door by lifting it up at the back side of the microwave. Remove and save the top and back retaining screws that hold the blower motor in the microwave.
Retaining screw
Retaining screw
3Carefully slide the blower motor toward the right, and lift it partially out of the opening. Note: The blower wires are long enough to allow flexible handling while performing these steps. Disconnect the wires only if it is necessary for additional flexibility.
Back of
Microwave
4Remove the two screws holding the gray colored inlet sleeve to the blower unit. Rotate the gray sleeve as shown until the gray arrow lines up with the “R”, Recirculating exhaust. Reinstall the two screws.
Remove screws from
Gray Inlet Sleeve
Back of Microwave
5Roll the assembled blower unit so that the
NOTE: The
| Black |
| Exhaust |
| Outlet Facing |
| the Front |
Must Face | Back of |
Downward | |
| Microwave |
20