Product – height 16 width 17depth 6

The system makes a good supply of drinking water each day.

How much it will make depends primarily on these things…

Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–125c

Feed water temperature limits—minimum/maximum degrees F. . . . . . . . . . . . . . . . . .40–100

Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000

Maximum water hardness @ 6.9 pH recommended to optimize membrane life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Safety Instructions Operating

For water with hardness greater than 10 grains (at 6.9 pH) the use of a softener is recommended. Failure to install a water softener will reduce the life of the Reverse Osmosis membrane. See chart for additional information on the possible need for a water softener.

Hp

nI oc nim Wg ta re

8

7.5

7

6.5

6

WATER SOFTENER RECOMMENDED

Water Softener

not required

10

20

30

40

50

60

INCOMING WATER HARDNESS (GPG)

Instructions

Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . .<0.1 Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Allowableb Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10Product (quality) water, 24 hours—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.0aProcess water per gallon of product water, 24 hours—gallons . . . . . . . . . . . . .5Percent rejection of TDS (new membrane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92a

Cyst reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99.95% Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3 Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes

Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12PA) Carbon Block Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12M) Thin Film Polyamid Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 16“ width 17” depth 6”

a.Tested by NSF International according to ANSI/NSF Standard 58 has given 7.1 GPD. Source water test parameters are 50 psig, 77°F, pH of 7.5 ± 0.5, and 750 ppm total dissolved solids.

b.Removed (maximum of 2.0 ppm) by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will destroy the Reverse Osmosis membrane.

c.If house water pressure is over 125 psi, install a pressure reducing valve in the water supply line. If house water pressure is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).

3

Installation Instructions Troubleshooting Tips Consumer Support

Page 3
Image 3
GE GXRV10ABL01 owner manual Specification guidelines, Safety Instructions Operating

GXRV10ABL01 specifications

The GE GXRV10ABL01 is a sophisticated variable frequency drive (VFD) designed to enhance efficiency in various industrial applications. Characterized by its versatility and advanced technologies, this device is ideal for controlling the speed and torque of electric motors, making it an integral component for modern automation systems.

One of the most notable features of the GE GXRV10ABL01 is its compact design, which allows for easy integration into existing systems without requiring significant modifications. This space-saving characteristic makes it suitable for a range of environments, including manufacturing floors, processing plants, and HVAC systems.

The GXRV10ABL01 is equipped with cutting-edge control technologies that improve performance and energy efficiency. It utilizes advanced algorithms for precise motor control, enabling smooth acceleration and deceleration while minimizing energy consumption. This enhances the overall efficiency of processes such as pumping, fans, and conveyors.

Another key feature is its robust communication capabilities. The GXRV10ABL01 supports a variety of communication protocols, including Ethernet/IP, Modbus, and Profinet. This interoperability allows for seamless integration with other control systems and facilitates real-time monitoring and data exchange, supporting Industry 4.0 initiatives.

User-friendly programming and operation are facilitated by the drive's intuitive interface. The built-in keypad allows for straightforward configuration and adjustments, while the ability to connect to external displays enhances usability. Furthermore, the drive supports various programming options, enabling customization to meet specific application requirements.

Safety features are paramount in the design of the GE GXRV10ABL01. It comes equipped with built-in protection mechanisms, including overcurrent, overvoltage, and thermal overload protection. These safety measures help to prevent damage to both the drive and connected machinery, ensuring reliable operation and longevity.

Durability is another hallmark of the GXRV10ABL01. Its rugged construction and high-quality components make it resilient against harsh environments, withstanding fluctuations in temperature, dust, and moisture. This makes it a dependable choice for diverse industrial applications.

In summary, the GE GXRV10ABL01 is a state-of-the-art variable frequency drive that combines advanced control technologies, robust communication capabilities, and essential safety features. Its compact design, user-friendly interface, and durability ensure it meets the demands of modern industrial automation, providing greater efficiency and reliability for critical operations.