Fusing of Tungsten Halogen Studio and Theatre Lamps

A lamp normally fails at end of life by fusing of the filament. Often an arc then forms and as there is little resistance to limit the current this rises to a very high value which if maintained can result in a serious overload on the envelope and seals. This might result in the lamp shattering. A quick acting high breaking capacity fuse must be connected in the supply line in all applications. Suitable types are given in BS88 (IEC 269), IEC 127 or IEC 241.

lamp

fuse (rated current)

 

 

 

 

 

power

(amps)

 

 

 

 

 

 

(watts)

100-115V

115-130V

220-250V

500

6

 

 

6

 

 

4

 

650

10

 

 

6

 

 

4

 

1000

16

(15

UK)

10

 

 

6

 

1500

20

 

 

16

(15

UK)

10

 

2000

25

(30

UK)

25

(20

UK)

10

 

2500

35

(30

UK)

25

(30

UK)

16

(15 UK)

5000

63

(60

UK)

50

 

 

25

(30 UK)

10000

125

 

100

 

50

 