Discharge lamps continued
1000 Watt CID Lamp Circuit Diagram
1000 Watt CSI/CID
| 20A |
| HBC/MCB |
| Fuse |
L |
|
220/240V | PFC |
50Hz | |
Supply | 175∝ F 250V |
| 7xGC2346 |
N |
|
Ballast G53307. T |
|
|
|
|
| 1000W CID Lamp | |
|
|
| Ref |
|
|
| or |
G53444 or | B | 9kV |
|
Bag Turgi | Lamp | ||
SE 15/7U | Lp |
| |
N |
|
| |
Igniter |
|
| |
|
|
| |
2.5W |
|
|
|
|
|
| |
250V |
|
|
|
| 20A |
| HBC/MCB |
| Fuse |
L |
|
220/240V | PFC |
50Hz | |
Supply | 175∝ F 250V |
| 7xGC2346 |
N |
|
Ballast G53307. T
Sw
Biassed Off
300V
G 3 2 2 1
Irem
AD1540
Igniter
HT
40kV
HT
1000W CSI Lamp
Ref
or
1000W CID Lamp
Ref
or
Lamp
Lampholder
Bender & Wirth
type 938/223
Lampholder for
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Replace G53445 (or Bag Turgi SE600/D) igniter sparkgap element when replacing a failed lamp
1200 Watt CID Hot-Restart Lamp Circuit Diagram
Sw - Normally open contacts - Manual switch or 2 second ON timer Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
2500 Watt CID
| 20A |
| HBC/MCB |
| Fuse |
L |
|
220/240V | PFC |
50Hz | |
Supply | 150∝ F 250V |
| 7xGC2346 |
N |
|
Ballast G53307. T
Sw
Biassed Off
250V
G 3 2 2 1
Irem
AD1550
Igniter
1200W CID Lamp
Ref
HT
50kV
HT
Lampholder
Bender & Wirth
type 938/223
| 40A |
| HBC/MCB |
| Fuse |
L |
|
220/240V | PFC |
50Hz | |
Supply | 275µF 250V |
| 11xGC2346 |
N |
|
Ballast 2xG53307. T in parallel
Sw
Biassed Off
G 3 2 2 1
Irem
AD3050
Igniter
HT
50kV
HT
2500W CID Lamp
Ref
Lampholder
Bender & Wirth
type 938/223
Sw - Normally open contacts - Manual switch or 2 second ON timer Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
Sw - Normally open contacts - Manual switch or 2 second ON timer Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
76GE LIGHTING - ENTERTAINMENT LIGHTING CATALOGUE