GE PBe manual Terminal IP/Camera Set-up menu, Terminal IP/camera set-up menu

Models: PBe

1 34
Download 34 pages 56.21 Kb
Page 20
Image 20

16

ProBridge Ethernet User Manual

the list will be selected. The PBe supports the following Ethernet devices:

Generic interface

Native ATM messages (FC)

Verifone POS

Ethernet data analyzer

Note: The Ethernet device can also be selected by DIP switch. See SW3 switches 1 to 8 on page 22.

Terminal IP/Camera Set-up menu

Selecting option #3 from the main menu launches the Terminal IP/Camera Set-up menu.

Figure 8. The terminal IP/camera set-up menu

Option #2 lets you associate cameras to terminals by the camera number and the terminals IP address. To associate a camera to a specific terminal do the following:

1.Press #2 and the enter key to display the camera/terminal list.

2.Enter the camera number that you want and the enter key.

3.Type in the IP address of the terminal to associate to the camera and press the enter key.

Page 20
Image 20
GE PBe manual Terminal IP/Camera Set-up menu, Terminal IP/camera set-up menu