No Water Circulation
YES
Check for clogged:
hub (remove lower wash arm) inlet cover
fine filter sump/sump filter
Attempt
to activate
circulation pump using
service mode (refer to Service
Mode chapter).
Does pump activate?
YES
Pump is stalled/clogged. Disconnect power and attempt to turn pump using cooling fins.
Motor capacitor is open/ shorted.
NO
Does
the pump
hum?
NO
| Important: |
|
| |
| Self tapping |
|
| |
|
| Check for an open | ||
| on pump must be tightened |
| circuit between control | |
Check pump for open/ | securely. |
| module and pump or | |
YES | NO | between pump and door | ||
shorted motor winding. | ||||
Is L1 voltage present at pump? |
| interlock switch. If | ||
|
| |||
| Note: Perform test with |
| circuits OK, replace | |
| wiring connected and |
| control module. | |
| pump under |
|
| |
| load. |
|
|
L1 Output from
CIRCULATION PUMP
NX
10
DOOR |
| ||
INTERLOCK |
| ||
WR | WX | N | |
NO | COM | ||
|
Fill Funnel | Rotate clockwise 1/4 turn to remove. |
The fill funnel is removable with a quarter turn clockwise. There is an
Calrod® Heating Element
The heating element can be activated using service mode. Refer to the Service Mode chapter.
The dual wattage Calrod® heating element draws 835 W when it is wet to heat the water faster and,