Installation Instructions

FAUCET ASSEMBLY

FAUCET MOUNTING INSTALLATION

Be sure there is room underneath the sink to make the needed connections. Select one of the following locations to install the faucet:

In an existing sink spray attachment or soap dispenser hole.

In a hole to be drilled in the sink top.

In a hole to be drilled in the countertop, next to the sink.

NOTE: Be sure the faucet base will fit flat against the surface at the selected location so the gasket will seal.

1.If drilling is needed, make a 1-1/4dia. hole. Be sure to use the proper procedure for drilling porcelain or stainless steel. Special drill bits may be needed. Consult a qualified plumber for proper procedure.

2.Remove the faucet, thin o-ring (D), faucet base (E), bottom base gasket (F), lock washer (G), hex nut (H) and mounting bracket (I) from the packaging.

3.Feed the 3/8blue banded, 1/4black tube

(attached to the Reverse Osmosis System) and the 3/8black tube (included in separate packaging) up through the mounting hole in the sink or countertop. This step may require two people to assemble. See page 14 for Optional

One Person Faucet Tubing Installation.

4.Feed the two black tubes up through the gasket (F), faucet base (E) and O-ring (D).

5.Push the 1/4black and 3/8black tubing onto their respective fittings on the body (B).

NOTE: To ease insertion, submerge tubing ends into hot water for a few minutes to soften.

6.Seat the base (E) and body (B) together. Make sure the O-ring and gasket are in place when the base meets the body. The faucet handle will be at the 3 o’clock position with respect to the base.

7.Slide the lock washer onto the threaded stem of the body (B), then thread the hex nut (H) onto the stem. Screw about halfway up.

NOTE: If installing faucet on a stainless steel sink, slide on installation spacer (M) before the lock washer.

8.Screw the blue tipped tubing adapter (K) onto the threaded stem of the body (B).

9.Push the blue banded tubing into the adapter. It should go in about 3/4. Pull on it to make sure it is installed correctly.

10.Feed the tubing, stem and power cord back down through the 1-1/4hole.

11.Lower the faucet assembly into place in the mounting hole and orient to final position. Place the mounting bracket (I) above the lock washer (G) around the faucet stem. While holding the mounting bracket in place, securely tighten the hex nut. This step may require two people.

Spout

Cap

Body (B)

Handle

ASSEMBLED

3/8barb fitting1/4barb fitting

 

Installation spacer (M)

 

(as needed)

3/8(black)

Lock washer (G)

Mounting bracket (I)

Power cord (L)

O-ring (D)

Base (E)

Gasket (F)

Lock washer (G) Hex nut (H)

Tubing adapter (K)

drain tubing

Hex Nut (H)

 

 

Tubing adapter (K)

1/4(black)

Power cord (L)

drain tubing

3/8(blue banded)

 

 

outlet tubing

NOTE: For ease of service and maintenance, keep tubing lengths long enough so removal of the Reverse Osmosis system from under the sink is possible.

13

To drain From RO From RO

Page 13
Image 13
GE PNRQ21LRB, PNRQ21LBN owner manual Faucet Assembly, Faucet Mounting Installation

PNRQ21LRB, PNRQ21LBN specifications

The GE PNRQ21LBN and PNRQ21LRB are two advanced models from General Electric's line of innovative HVAC (Heating, Ventilation, and Air Conditioning) solutions. Designed with both efficiency and performance in mind, these units cater to residential and commercial needs, ensuring comfort in a variety of settings.

One of the standout features of the PNRQ21LBN and PNRQ21LRB is their energy efficiency. Both models utilize GE's cutting-edge inverter technology, which allows for variable speed operation. This means that the compressor can adjust its output based on the specific cooling or heating needs, leading to significant energy savings while maintaining optimal indoor climates. As a result, these units are not only environmentally friendly, but also cost-effective over time.

Another key characteristic is their quiet operation. The engineers at GE have invested in sound-dampening technologies that minimize operational noise, allowing users to enjoy a peaceful atmosphere, whether in a home, office, or commercial space. This is particularly beneficial for areas where noise sensitivity is crucial, such as bedrooms or conference rooms.

The PNRQ21LBN and PNRQ21LRB also come equipped with advanced air filtration systems. These systems effectively remove dust, allergens, and other airborne particles, contributing to improved indoor air quality. The filters are easily accessible for maintenance, ensuring that users can keep their systems running at peak performance with minimal effort.

User-friendly interfaces are another hallmark of these GE models. They feature intuitive control options that allow users to set schedules, adjust temperature preferences, and even monitor energy usage. This level of control empowers users to optimize their HVAC systems according to their lifestyle and needs.

In terms of design, both models boast a sleek and modern aesthetic, making them suitable for various architectural styles. They can fit seamlessly into any environment, enhancing the overall appeal of the space.

Overall, the GE PNRQ21LBN and PNRQ21LRB exemplify a blend of efficiency, quiet operation, advanced filtration, and user-centric design, making them ideal choices for anyone looking to enhance comfort and improve energy efficiency in their living or working environments.