GE PNRQ21LRB, PNRQ21LBN Specification guidelines, Product - height 11 ″ width 10.5 ″ depth 4 ″

Models: PNRQ21LRB PNRQ21LBN

1 84
Download 84 pages 58.72 Kb
Page 3
Image 3
Specification guidelines.

Specification guidelines.

ge.com

Product – height 11 width 10.5 depth 4

The system makes a good supply of drinking water each day.

How much it will make depends primarily on these things…

Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–120a

Feed water temperature limits—minimum/maximum degrees F . . . . . . . . . . . . . . . . .40–100Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000

Maximum water hardness @ 6.9 pH recommended to optimize membrane life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Safety Instructions Operating

For water with hardness greater than 10 grains (at 6.9 pH), the use of a softener is recommended. Failure to install a water softener will reduce the life of the Reverse Osmosis membrane. See chart for additional information on the possible need for a water softener.

Hp

aW rte

cIn mo gin

8

7.5

7

6.5

6

WATER SOFTENER RECOMMENDED

Water Softener

not required

10

20

30

40

50

60

INCOMING WATER HARDNESS (GPG)

Instructions Installation
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . .<0.1

Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm Maximum Allowableb Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10

Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4c

Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes

Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROPF) Carbon Block Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROMF) Thin Film Polyamide Storage Tank Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 15” diameter 11” System Body Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 11” width 10.5” depth 4”

a.If house water pressure is over 120 psi, install a pressure reducing valve in the water supply line. If house water pressure is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).

b.Removed (maximum of 2.0 ppm) by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will destroy the Reverse Osmosis membrane.

c.Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure, tank capacity is 2.3 gallons.