&yPRXVDUODVXQLGDGHVGHVXSHUILFLH

6HOHFFLyQ

GHODXQLGDG 6HOHFFLyQGHOD

GHVXSHUILFLH XQLGDGGHVXSHUILFLH

SHTXHxDGH JUDQGHGH

8QLGDGGHVXSHUILFLHGREOH

/DXQLGDGGHVXSHUILFLHIURQWDOGHUHFKDWLHQH

GRVWDPDxRVSDUDFRFLQDUHQWUHORVTXHXVWHG

SXHGHHVFRJHU\DVtSRGUiFRPELQDUHOWDPDxR

FRUUHFWRGHODVDUWpQTXHVHHQFXHQWUHXVDQGR

FRQODXQLGDGGHVXSHUILFLHDSURSLDGD

3DUDXVDUXQDXQLGDGGHVXSHUILFLHJUDQGH  

JLUHHOERWyQHQGLUHFFLyQGHODVDJXMDVGHOUHORM

KDFLD \VHOHFFLRQHHODMXVWHGHVHDGR/D

XQLGDGFDOHQWDUiHOiUHDFRPSOHWDFRQWHQLGD

HQHOFtUFXORJUDQGH

3DUDXVDUODXQLGDGGHVXSHUILFLHSHTXHxD   JLUHHOERWyQHQGLUHFFLyQFRQWUDULDDODVDJXMDV GHOUHORM\VHOHFFLRQHHODMXVWHGHVHDGR/D XQLGDGFDOHQWDUiVRODPHQWHHOiUHDFRQWHQLGD HQHOFtUFXORSHTXHxR

8QLGDGGHVXSHUILFLHGHSXHQWH

4XHPDGRU

IURQWDO 4XHPDGRU

VRODPHQWH IURQWDO\ SXHQWH

&HUFLyUHVHGHTXHODVDUWpQGHVFDQVDGHPDQHUD

(VFRMDVDUWHQHVTXHKDJDQMXHJRFRQHOiUHD

SODQDVREUHODHVWXIDGHYLGULR\GHTXHQRHVWi

FLUFXODUSXHQWHWDQWRFRPRVHDSRVLEOH

GHVFDQVDQGRHQORVH[WUHPRV6LXVWHGQRWDSRFR

3DUDXVDUVRODPHQWHODXQLGDGGHVXSHUILFLH

UHQGLPLHQWRGHFRFFLyQPXHYDODVDUWpQSDUD

IURQWDOJLUHHOERWyQGHOTXHPDGRUKDFLD

 



 

FHUFLRUDUVHGHTXHHVWiDSR\DGDGHPDQHUD

 

\VHOHFFLRQHHODMXVWHGHVHDGR/DXQLGDG

SODQDVREUHODHVWXID

FDOHQWDUiHOTXHPDGRUGHVXSHUILFLHIURQWDO

3DUDXVDUHOTXHPDGRUGHSXHQWHJLUHHOERWyQ

8VWHGSXHGHFUHDUXQiUHDGHFDOHQWDPLHQWR

GHOTXHPDGRUKDFLD

 

\VHOHFFLRQHHODMXVWH

 

REORQJDXVDQGRODFRPELQDFLyQGHODXQLGDG

GHVHDGR/DXQLGDGFDOHQWDUiODVXSHUILFLHIURQWDO

SRVWHULRUL]TXLHUGD\HOSXHQWHGHODXQLGDG

\HOSXHQWH

IURQWDO

/RVHOHPHQWRVGHVXSHUILFLHVHHQFLHQGHQ\DSDJDQ

/RVHOHPHQWRVGHVXSHUILFLHVHHQFLHQGHQ\

DSDJDQSDUDPDQWHQHUODWHPSHUDWXUDTXH XVWHGKDVHOHFFLRQDGR

7RGRVORVHOHPHQWRVGHVXSHUILFLHFXHQWDQFRQ XQOLPLWDGRUGHWHPSHUDWXUDTXHSURWHJHOD HVWXIDGHYLGULRGHFDOHQWDUVHGHPDVLDGR

(OOLPLWDGRUGHWHPSHUDWXUDSXHGHDSDJDUORV HOHPHQWRVGXUDQWHODFRFFLyQVL

(OUHFLSLHQWHKLHUYHHQVHFR

/DEDVHGHOUHFLSLHQWHQRHVSODQD (OUHFLSLHQWHQRHVWiFHQWUDGR 1RKD\XQUHFLSLHQWHHQHOHOHPHQWR

/LPLWDGRUGHWHPSHUDWXUD

&DGDXQLGDGGHVXSHUILFLHUDGLDQWHWLHQHXQ OLPLWDGRUGHWHPSHUDWXUD

(OOLPLWDGRUGHWHPSHUDWXUDSURWHJHODHVWXID GHYLGULRGHFDOHQWDUVHGHPDVLDGR

(OOLPLWDGRUGHWHPSHUDWXUDSRGUtDKDFHUTXHOD

XQLGDGHQWUHHQFLFORDSDJDGRVL

/DHVWXIDHVWiHQFHQGLGDPLHQWUDVVHFRFLQD /DVDUWpQKLHUYHYDFtD (OIRQGRGHODVDUWpQQRHVSODQR /DVDUWpQQRHVWiFHQWUDGD 1RKD\VDUWpQVREUHODXQLGDG

%ORTXHRGHFRQWUROGHODVXQLGDGHVGHVXSHUILFLH

3DUDDFWLYDUHOEORTXHRGHFRQWUROJLUHOD SHULOOD&RQWURO/RFN %ORTXHRGHFRQWURO D /2&. %ORTXHR (VWRQRSHUPLWLUiTXHODV XQLGDGHVGHVXSHUILFLHVHFDOLHQWHQ8QDOX] LQGLFDGRUDVHHQFHQGHUiSDUDGHPRVWUDUTXH HVWiQEORTXHDGDV(OYHQWLODGRUGHFRUULHQWH

GHVFHQGHQWHSHUPDQHFHUiRSHUDEOHFRQHO

EORTXHRGHFRQWURODFWLYDGR

(QODSRVLFLyQEORTXHDGDODHVWXIDSURGXFLUi

XQVRQLGRDXGLEOHVLFXDOTXLHUSHULOODGHFRQWURO GHXQLGDGGHVXSHUILFLHVHDFWLYDRJLUDDRWUD SRVLFLyQTXHQRVHD2)) $SDJDGR 

&yPRRSHUDUHOVLVWHPDGHYHQWLODFLyQ

(OVLVWHPDGHYHQWLODFLyQLQFRUSRUDGRD\XGDD

(OXVRFRQWLQXRGHOVLVWHPDGHYHQWLODFLyQ

UHPRYHUORVYDSRUHVGHODFRFLQDORVRORUHV\HO PLHQWUDVFRFLQDD\XGDDPDQWHQHUODFRFLQD

KXPRGHODVFRPLGDVSUHSDUDGDVHQODHVWXID

FyPRGD\PHQRVK~PHGDUHGXFLHQGR

3DUDRSHUDUHOVLVWHPDGHYHQWLODFLyQGH

ORVRORUHVGHFRFLQD\ODKXPHGDGTXH

DLUHGHVFHQGHQWH GRZQGUDIW JLUHHOERWyQ

QRUPDOPHQWHFUHDODQHFHVLGDGIUHFXHQWHGH

GHFRQWUROGHODYHORFLGDGGHOYHQWLODGRUGH

OLPSLH]D

YHQWLODFLyQD+, $OWR 0(' 0HGLR R/2 %DMR  VHJ~QVHDQHFHVDULR

Page 36
Image 36
GE PP989 owner manual YprXvduOdvXqlgdghvGhVxshuilflh, 8QLGDGGHVXSHUILFLHGHSXHQWH

PP989 specifications

The GE PP989 is a sophisticated industrial gas turbine, designed to meet the demands of power generation and providing efficient solutions for various energy applications. One of its primary innovations lies in its ability to operate on a diverse range of fuels, which makes it highly adaptable in different regions and market conditions. This flexibility enhances its appeal to businesses looking for reliable energy solutions.

One of the standout features of the GE PP989 is its high thermal efficiency, achieved through advanced combustion technology that minimizes emissions while maximizing output. This technology not only contributes to environmental sustainability but also ensures compliance with increasingly stringent emissions regulations globally. The gas turbine is equipped with sophisticated control systems that optimize performance and maintain high reliability throughout its operation.

The PP989 utilizes a modular design, which allows for easier maintenance and reduced downtime. This characteristic is crucial for industrial operators who need consistent energy supply without significant interruptions. Its modularity extends to its components, enabling quick replacements and upgrades, thus proactively addressing any operational challenges.

Another key technological aspect of the GE PP989 is its integration with digital capabilities through GE's Digital Wind Farm solutions. This integration offers real-time monitoring and data analysis, empowering operators with insights that enhance decision-making and operational efficiency. The turbine’s connectivity features allow for remote diagnostics, ensuring timely maintenance and minimizing the risk of unexpected failures.

In terms of operational characteristics, the GE PP989 boasts an impressive output capability, making it suitable for both base-load and peak-load applications. It can quickly ramp up or down to meet fluctuating energy demands, which is particularly beneficial in today's energy landscape, where renewable sources often lead to variable supply.

The turbine's design also emphasizes noise reduction and operating safety, ensuring minimal disturbance to surrounding communities while maintaining a safe operational environment for personnel. With a commitment to reliability and performance, the GE PP989 stands as a leading choice for operators in the energy sector, blending advanced technology with practical applications in energy production. Its combination of efficiency, flexibility, and cutting-edge design reaffirms GE's position at the forefront of the power generation industry.