GE PVB67, PVB98, PVB37, PVB94 Installation Instructions, Install Downdraft Vent, Install Ductwork

Models: PVB67 PVB94 PVB37 PVB98

1 32
Download 32 pages 23.19 Kb
Page 11
Image 11
Installation Instructions

Installation Instructions

1 INSTALL DOWNDRAFT VENT

Place the downdraft vent into the countertop cutout, against the back side.

Bracket location for right-side or straight- down blower discharge

Support

 

 

Support

Bracket

A

B

Bracket

 

 

 

 

 

Top View of

 

 

 

Support Bracket

Locate the brackets and attachment screws.

On some models, the attachment screws may be placed on the control box in position A or B.

Fasten one bracket to each side rail, position A and B, and secure to the cabinet back wall.

Bracket location for left-side blower discharge

B Support

1 INSTALL DOWNDRAFT VENTBracket location for right-side or straight- down blower dischargeBracket

C

Support

Bracket

Top View of

Support Bracket

Locate the brackets and attachment screws.

On some models, the attachment screws may be placed on the control box in position A or B.

Use location C on the control box instead

of location A for left discharge orientation of the blower.

• When installing in

A

a tile countertop

 

surface, it may be

C

necessary to apply

 

a locally approved caulking to cover any gaps.

2INSTALL DUCTWORK

The downdraft blower system is designed for use with 3-1/4" x 10" ductwork. It can be transitioned to 6" round.

Ductwork MUST be vented to the outside—never in a crawl space, attic or other enclosed space.

6" PVC duct should be used when installing under a concrete slab.

NOTE: Local building code must be followed for installation in specifying approved type and schedule of PVC duct used.

Duct Tape

Over Seam and Screw

Air

Flow

Screw

DO NOT USE flexible plastic ducting.

Always use appropriate roof or wall cap with damper. Laundry-type wall caps should never be used.

Use the straightest duct run possible.

For satisfactory performance, the duct run should not exceed 150 ft. or its equivalent length when bends or various fittings are used. Refer to the table of equivalent lengths to calculate your installation.

Install ductwork so the piece of duct nearest the downdraft unit slots INTO the next piece of the duct. Secure the joints with self-tapping screws and apply duct tape around the joints to ensure an airtight seal.

11

Page 11
Image 11
GE PVB67, PVB98, PVB37, PVB94 installation instructions Installation Instructions, Install Downdraft Vent, Install Ductwork