POWER SUPPLY

Installation Preparation

POWER SUPPLY

Gas Cooktops WARNING:

For personal safety, this appliance must be properly grounded.

Remove house fuse or open circuit breaker before beginning installation.

Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Code or prevailing local codes and ordinances.

This downdraft vent must be supplied with 120V, 60 Hz. and connected to an individual, properly grounded branch circuit, protected by a 15-

or 20-ampere circuit breaker or time-delay fuse.

Gas Cooktops

If this vent is installed in combination with a GE or Monogram gas cooktop, it may operate from the same duplex outlet.

Electric Cooktops

If this vent is installed in combination with a GE or Monogram electric cooktop, the vent must operate from a separate 120V outlet.

A properly grounded 3-prong receptacle should be located within reach of the vent’s two-foot power cord.

Locate the receptacle inside the cabinet on the right side wall. The receptacle cannot be placed on the back of the cabinet wall where it may interfere with the downdraft plenum.

See illustration.

Ensure that the cooktop is installed per manufacturer’s installation instructions.

Do Not Locate Gas or Electrical

Connections Within Shaded Area

29-1/2"

Electric Cooktops Electrical

Outlet

12" Above Cabinet Floor

(Please read carefully.) 34" for 36" Models Manual background

28-1/2" for 30" Models

IMPORTANT

(Please read carefully.)

The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has correct polarity.

Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

DO NOT USE AN EXTENSION CORD.