GE PVB37, PVB98, PVB94 Clearances, Ductwork, Electrical and Gas Locations, Design Information

Models: PVB67 PVB94 PVB37 PVB98

1 32
Download 32 pages 23.19 Kb
Page 5
Image 5
Clearances

Design Information

Clearances

The downdraft system with blower, motor and ductwork will occupy the cabinet below the countertop and cooktop.

The blower/motor assembly can be located below the cabinet floor. The assembly will fit between 16" floor joists. Order JXRB67 for indoor remote locations.

The blower motor assembly can also be installed outdoors. Order JXBC67 for remote blower installations outdoors.

Refer to Clearances for information

on appropriate placement and necessary clearances when planning installation.

Refer to your specific cooktop installation instruction for other appropriate clearances.

Avoid placing cabinetry directly above the cooking surface when possible.

If cabinetry is used above the cooking surface:

Use cabinets no more than 13" deep.

Maintain 30" minimum clearance between cooktop and unprotected cabinets directly above cooktop.

If clearance is less than 30", protect cabinet bottoms with flame-retardant millboard at least 1/4" thick or gypsum board at least 3/16" thick covered with 28 gauge sheet steel or .02" thick copper.

Clearance between cooktop and protected cabinetry must not be less than 24".

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

Working areas adjacent to the cooktop should have 18" minimum clearance between countertop and cabinet bottom.

Installation must conform with local codes.

Ductwork

Prepare ductwork to vent to the outdoors.

Use the shortest and straightest duct run possible.

The maximum permissible length for duct run is 150 feet.

Refer to “Duct Fittings” chart to calculate equivalent length for various duct configurations.

The downdraft blower system is designed to use

3-1/4" x 10" ductwork. It can be transitioned to 6" round.

Ductwork MUST be vented to the outside–never into a crawl space, attic or other enclosed space.

Determine the need for a wall cap or roof cap.

Order the cap in advance.

Electrical and Gas Locations

Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be placed on the back wall of the cabinet because it may interfere with the downdraft plenum.

Install a standard electrical outlet within reach of the vent’s two-foot-long power cord.

The vent and a GE or Monogram gas cooktop combination can operate from the same 120-volt standard duplex outlet.

Electric cooktops must operate from a separate

240-volt junction box.

5

Page 5
Image 5
GE PVB37, PVB98, PVB94, PVB67 installation instructions Clearances, Ductwork, Electrical and Gas Locations, Design Information