Installation Instructions
STEP 2B Alternate Mounting Method
INSTALL HOOD TO SOFFIT OR BENEATH CABINETS
SKIP THIS STEP IF USING WALL MOUNTING METHOD
When necessary, the hood may be installed so that it is supported by the soffit.
IMPORTANT: Soffit framing must be capable of supporting up to 150 lbs.
Install Transition Onto Top of Hood
•The soffit should be constructed with 2 x 4’s.
•Determine the installation location on the wall.
•Continue the centerline forward on the bottom of the cabinet or soffit.
•The opening above the hood should allow for the 10" round duct and clearance to slide the hood back against the wall.
Requires
Opening For Ductwork
and Hood Installation
IMPORTANT: Remove shipping tape from damper and check that damper moves freely.
Duct
Transition
of Top Hood
A
A
•The 2 x 4 studs must be located as shown in the chart, Dim. A. to accept mounting screws.
|
|
|
|
|
|
|
|
|
|
|
|
| “A” |
|
| “B” | ||||||
|
|
|
|
|
|
|
| Centerline to Stud |
|
| Hood Width | |||||||||||
|
|
|
|
|
|
|
| and Keyhole Slots |
|
| At the Top | |||||||||||
ZV48R |
|
|
|
| ||||||||||||||||||
ZV36R |
|
|
|
| ||||||||||||||||||
ZV30R |
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Top View | |||
2" |
|
|
|
|
|
|
| A |
|
|
|
|
|
|
|
| Front of Hood | |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
8" |
|
|
|
| C |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6" |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Back of Hood
•Drill 1/8" pilot holes into the studs at the locations shown in the top view illustration.
•Place the transition piece over the hood exhaust and secure with 4 screws provided.
•Use duct tape to seal the connection. Check to be sure the damper moves freely.
Mount Hood onto Soffit or Cabinet
Note: If mounting to the underside of a cabinet with a recessed bottom, install shims to fill the gap.
Soffit
|
|
|
|
|
|
|
|
| |
Engage Top |
|
|
|
| Add Shims | ||||
1/4" Gap | |||||||||
Keyhole Slots |
| If Bottom | |||||||
|
|
|
| ||||||
|
|
|
|
|
|
|
| Is Recessed | |
|
|
|
| Push Back |
| Back | |||
|
|
|
| to Wall |
| ||||
|
|
|
|
| Wall | ||||
|
|
|
|
|
|
|
|
•Drive mounting screws into the studs until they protrude 1/4". The 1/4" gap will provide clearance to engage the keyhole slots in the top of the hood.
•Lift hood to installation position. Locate house wiring and route through the knockout (from the back or top of the hood).
•Lift hood onto mounting screws. Slide back against the rear wall.
•Tighten mounting screws.
IMPORTANT: For additional support and to minimize vibration during operation, the hood must be secured to the back wall. Use wall anchors to fasten bottom back of hood to the wall.