GE ZV48R, ZV36R Determine Installation HEIGHT, Duct Cover Accessories, Restaurant-Style Hoods

Models: ZV48R ZV30R ZV36R

1 16
Download 16 pages 26.26 Kb
Page 5
Image 5

Advance Planning

DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES

These vent hoods must be installed 30" min. to 36" max. above the standard 36" high cooking surface. When installed with the warming shelf, allow 32" min. to 38" max. clearance. The exact hood installation height is determined by the ceiling height.

1.Measure the exact ceiling height.

2.Review the chart at right to determine the range of possible hood installation heights that can be accomplished with one or more duct covers.

3.Increase or decrease hood installation height to accommodate the fixed 6" or 12" duct covers.

4.Duct covers may be stacked, in various combinations, to reach ceiling heights.

 

 

Restaurant-Style Hoods

Restaurant-Style Hoods

 

without Warming Shelf Installed

with Shelf Installed1

 

 

*Possible

 

 

*Possible

 

 

 

Actual

Hood

 

 

Hood

 

 

 

Ceiling Installation

6" Duct

12" Duct

Installation

6" Duct

12" Duct

 

Height

Height

Covers

Covers

Height

Covers

Covers

 

7' 11"

31"

1

1

37"

 

1

8' 0"

32"

1

1

32"

1

1

 

8' 0"

 

 

 

38"

 

1

 

8' 1"

33"

1

1

33"

1

1

8' 2"

34"

1

1

34"

1

1

 

 

 

 

 

 

 

 

 

8' 3"

35"

1

1

35"

1

1

8' 4"

30"

 

2

 

 

 

8' 4"

36"

1

1

36"

1

1

 

 

 

 

 

 

 

 

8' 5"

31"

 

2

37"

1

1

Duct Cover(s) 10"

30" Min.

36" Max.

Ceiling Height to Floor

Duct Cover(s) 10"

32" Min. 38" Max.

Ceiling Height to Floor

8' 6"

32"

 

2

32"

 

2

8' 6"

 

 

 

38"

1

1

 

 

 

 

 

 

 

8' 7"

33"

 

2

33"

 

2

8' 8"

34"

 

2

34"

 

2

8' 9"

35"

 

2

35"

 

2

 

 

 

 

 

 

 

8' 10"

30"

1

2

 

 

 

8' 10"

36"

 

2

36"

 

2

8' 11"

31"

1

2

37"

 

2

 

 

 

 

 

 

 

9' 0"

32"

1

2

32"

1

2

9' 0"

 

 

 

38"

 

2

9' 1"

33"

1

2

33"

1

2

 

 

 

 

 

 

 

9' 2"

34"

1

2

34"

1

2

9' 3"

35"

1

2

35"

1

2

9' 4"

30"

 

3

 

 

 

9' 4"

36"

1

2

36"

1

2

Note: When determining the installation height, consideration must be given to the use of the warming shelf.

9' 5"

31"

 

3

37"

1

2

9' 6"

32"

 

3

32"

 

3

9' 6"

 

 

 

38"

1

2

9' 7"

33"

 

3

33"

 

3

9' 8"

34"

 

3

34"

 

3

 

 

 

 

 

 

 

9' 9"

35"

 

3

35"

 

3

9' 10"

30"

1

3

 

 

 

9' 10"

36"

 

3

36"

 

3

 

 

 

 

 

 

 

9' 11"

31"

1

3

37"

 

3

10' 0"

32"

1

3

32"

1

3

10' 0"

 

 

 

38"

 

3

*Based on 36" countertop height.

Note: Additional duct covers may be used to reach higher ceilings.

5

Page 5
Image 5
GE ZV48R, ZV36R, ZV30R Determine Installation HEIGHT, Duct Cover Accessories, Restaurant-Style Hoods