8
WARNING: SAFETY PRECAUTIONS
Do not use the grill until a leak test has been
performed.
WARNING:
TEST FOR LEAKSA complete gas tightness check must
be performed at the installation site.
To prevent fire or explosion hazard, DO NOT
use or permit sources of ignition in the area
while performing a leak test. Perform leak
test outdoors only. Never perform a leak test
with fire or flame. DO NOT SMOKE WHILE
PERFORMING THE LEAK TEST.
• Create a soapy solution of equal parts mild
dishwashing detergent and water.
• Check to be sure all controls are in the OFF
position.
• Turn on the fuel supply. For natural gas, turn
manual shut-off valve handle 1/4 turn to align
with gas flow. For LP, turn cylinder valve knob
counterclockwise one full rotation.
• Apply soap solution generously on all
connections and fittings. See illustrations.
• If growing bubbles appear on any connection
point, IMMEDIATELY turn off the gas supply.
To stop a gas leak:
• Turn on control knobs to release pressure.
Turn controls OFF.
• Wash off soapy solution and towel dry.
• Tighten the loose joint and perform a new
leak test.
Important Safety Instructions
Professional Outdoor Grills & Cooktops