TELNET CONTROL

The Gefen 4x1 DisplayPort Switcher supports Telnet for controlling the Switcher over a network. To access this feature, an IP address, subnet, gateway, and port numbers need to be set correctly. Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate with the Switcher over a network.

The Telnet control must be configured using RS-232 commands. Once properly configured, enter the IP address that was assigned to the Switcher using a terminal program or other Telnet client.

1.Connect the Switcher to a computer using RS-232.

2.Use a terminal emulation program (e.g. HyperTerminal, PuTTY, Indigo, etc.) to connect to the Switcher. See page 14 for information on RS-232 configuration.

IMPORTANT: When using HyperTerminal under Windows XP, the LF (line feed) character option must be enabled.

3.Apply power to the Switcher. Information similar to the following will be displayed in the terminal window:

===================================================

GEFEN

DISPLAY PORT 441 FW version: 1.3

===================================================

4.Use the #ipconfig command to display the current IP settings. The factory (default) settings are displayed below:

#ipconfig

 

-------------------

TCP/IP settings ---------------

MAC addr

= 00:1C:91:02:40:00

IP addr

= 192.168.0.70

Net Mask

= 255.255.255.0

Gateway

= 192.168.0.1

Web Server Port

= 80

Telnet Server Port

= 23

Telnet password on login is set to ON

Note that the Telnet password is set to ON. A user name and password can be set for additional security. This option can also be disabled. See page 20 for details.

24

Page 27
Image 27
Gefen EXT-DP-441 manual Telnet Control, Gefen