Generac 004700-0 Location And Support, Generator Location, Generator Support, Suspended Mounting

Models: 004700-0

1 52
Download 52 pages 28.33 Kb
Page 24
Image 24
2.1LOCATION AND SUPPORT

Section 2 – Installation

QUIETPACT 40G Recreational Vehicle Generator

2.1LOCATION AND SUPPORT

2.1.1 GENERATOR LOCATION

The most desirable location for the generator set is between the vehicle's main frame members. However, this is seldom possible. Most units must be installed on the side of the vehicle and are difficult to reinforce.

Many recreational vehicles have been factory equipped with an area for the generator set. Some vehicles may even have a generator compartment provided by the vehicle manufacturer.

Plan the generator location based on the following:

The generator set must be installed on a frame- work that is part of the recreational vehicle, as out- lined in Section 2.1.2.

The location must provide an access opening that is large enough to permit generator removal (unless the generator is to be removed from under- neath the supporting framework).

The location must provide easy access to frequent- ly serviced components, such as filters, oil drains, spark plugs and other common maintenance parts.

The location must provide sufficient room to allow minimum clearances as outlined in Section 2.2. If sound insulation is to be used on the compartment walls and ceiling, the minimum recommended applies to the space between the generator and such insulation.

The location must provide adequate cooling and ventilating airflow for the generator without a great deal of work and expense.

2.1.2 GENERATOR SUPPORT

The generator must be securely attached to a metal framework that has been made part of the vehicle frame structure by bolting or welding. The metal framework on which the generator will rest and which will restrain the generator set should consist of at least two horizontal beams. These beams should consist of (a) 1-1/2-inch square, 11-gauge steel tubing OR (b) 1-1/2-inch, 11-gauge angle iron. A typical sup- porting frame with horizontal support tubing, is shown in Figure 2.1.

The generator can be installed so that it sits on top of the horizontal support tubing if the vehicle design permits. Another method is to suspend the generator below the horizontal support tubing by means of suit- able, structurally sound metal framework. The fol- lowing general rules apply:

Vehicle construction MUST be capable of support- ing the weight of the generator.

Whether the generator is mounted above the hori- zontal support tubing or suspended below the tub- ing, the supporting frame used must be structural- ly sound.

If the generator cannot be bolted directly to the supporting frame or support tubing, consider

using additional tubing, angle brackets or other supports to give the supporting frame suf- ficient strength.

Figure 2.1 – Typical Horizontal Support Frame

2.1.3 SUSPENDED MOUNTING

If you are going to suspend the generator below the horizontal support tubing, the suspension method you use with the vehicle frame members must (a) be able to support the weight of the generator AND (b) provide sufficient restraint for the generator. One typ- ical suspended mounting system is shown in Figure

2.2.The location of a suspended mounting system must be carefully planned, keeping the following gen- eral rules in mind:

Protect the generator against road splash and debris. Baffles or splash guards may be required to protect certain areas of the generator. To make sure the gen- erator is adequately protected, road test the installa- tion through mud, water and slush.

Figure 2.2 – Typical Suspended Mounting System

GENERATOR SUPPORT FRAME (MODEL 004718-0)

GENERATOR MOUNTING

HOLES FOR 5/16" - 18

BOLTS (6 PLACES)

The installer must make certain that the selected location will permit adequate cooling and ventilat- ing airflow to be supplied.

22 Generac® Power Systems, Inc.

Page 24
Image 24
Generac 004700-0 owner manual Location And Support, Generator Location, Generator Support, Suspended Mounting