◆2.9.3 FIELD BOOST

Section 2 – Operation

QUIETPACT 40G Recreational Vehicle Generator

2.9.3 FIELD BOOST

The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.3). During engine cranking only, a positive DC (battery) voltage is deliv- ered through the diode, resistor, brushes and slip rings, to the generator rotor. Application of this volt- age to the rotor “flashes the field” whenever it is start- ed. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings.

Figure 2.3 – Field Boost Circuit

The voltage regulator also incorporates a “voltage surge protection circuit.” This circuit prevents trou- blesome surges in the generator AC output voltage. Voltage surge is a common cause of damage to elec- tronic equipment.

2.10 ADDITIONAL INFORMATION

2.10.1 25-HOUR BREAK-IN PERIOD

The first 25 hours of operation is the break-in period for the generator. Properly breaking in the generator is essential to minimize fuel consumption and pro- vide maximum engine performance. During this 25- hour break-in period, follow this procedure:

Run the unit at varying electrical loads to help seat the engine piston rings properly.

Check the engine oil level frequently. Add oil if needed. It is normal for the generator engine to consume more oil than is normal until the piston rings have properly seated.

For the 75-hour operation following the break-in period, avoid light electrical loads. Load the generator at 50 percent (or more) of its rated wattage capacity. Repeated light loads during these 75 hours can cause improper seating of engine pis- ton rings, resulting in blowby and high oil con- sumption.

After operating the unit for 25 hours, complete the tasks recommended under Section 2.10.2.

2.9.4 OVERVOLTAGE PROTECTION

A solid-state voltage regulator (Figure 2.4) controls the generator’s AC output voltage. This regulator sup- plies an excitation current to the rotor. By regulating the rotor’s excitation current, the strength of its mag- netic field is regulated and, in turn, the voltage deliv- ered to connected electrical loads is controlled. When the AC frequency is 60 Hertz, voltage is regulated at 120 volts (voltage-to-frequency ratio is 2-to-1).

Figure 2.4 – Solid State Voltage Regulator

2.10.2 25-HOUR CHECK-UP

After the 25-hour break-in period, contact a Generac Authorized Service Dealer for the following mainte- nance. The vehicle owner is responsible for any charges:

Change the engine crankcase oil and oil filter.

Check the oil level.

Inspect the cooling and ventilation openings.

Check the engine carburetor adjustments.

Check the engine ignition system.

Inspect the entire electrical system.

Inspect the engine exhaust system.

2.10.3 ATTENTION REQUIRED

AFTER SUBMERSION

If the recreational vehicle generator has been sub- merged in water, it MUST NOT be started and oper- ated. Following any submersion in water, have a Generac Authorized Service Dealer thoroughly clean and dry the generator.