Generac 005308-0 Operation, Know The Generator, 1512, Control Panel, Generator Controls

Models: 005308-0

1 48
Download 48 pages 21.14 Kb
Page 8
Image 8
Section 2 – Operation

Section 2 – Operation

Residential Portable Generator System

OPERATION

1)

12 Volt DC, 10 Amp Receptacle – This receptacle allows the

 

 

capability to recharge a 12 volt DC storage battery with

2.1 KNOW THE GENERATOR

 

provided battery charge cables.

2)

120 Volt AC, 20 Amp, Duplex Receptacle – Supplies

 

Read the Owner’s Manual and Safety Rules before operating

 

electrical power for the operation of 120 Volt AC, 20 Amp,

this generator.

 

single-phase, 60 Hz electrical lighting, appliance, tool and

Compare the generator to this illustration to become familiarized

 

motor loads.

3)

120 Volt AC, 20A Duplex GFCI Receptacle

with the locations of various controls and adjustments. Save this

 

Supplies ground fault protected electrical power for

manual for future reference.

 

 

operation of 120 volt AC 20 amp, single-phase, 60 Hz electric

 

 

Figure 4 - Control Panel

 

lighting, appliances, tools and motor loads.

4)

120 Volt AC, 30 Amp Locking Receptacle – Supplies

 

 

 

electrical power for the operation of 120 Volt AC, 30 Amp,

 

 

single-phase, 60 Hz electrical lighting, appliance, tool and

 

 

motor loads.

 

5)

120/240 Volt AC, 30 Amp Locking Receptacle – Supplies

 

 

electrical power for the operation of 120 and/or 240 Volt AC,

 

 

30 Amp, single-phase, 60 Hz, electrical lighting, appliance,

 

 

tool and motor loads.

 

6)

120/240 Volt AC, 50 Amp Receptacle (Located on

 

 

underside of control panel)– Supplies electrical power for

 

 

the operation of 120/240 Volt AC, 50 Amp, single-phase, 60

 

 

Hz, welder or motor loads.

 

7)

Air Cleaner – Filters intake air as it is drawn into the engine.

 

8)

Choke Knob – Used when starting a cold engine.

 

9)

Winter / Summer Valve – See “Cold Weather Operation.”

 

 

(Section 2, page 12.)

 

10)

Circuit Breakers (AC) – Each receptacle is provided with a

 

 

push-to-reset circuit breaker to protect the generator against

Figure 5 - Generator Controls

 

electrical overload. (50 amp uses toggle reset)

11)

Fuel Tank – Tank holds 16 U.S. gallons of fuel.

 

7 11

12)Grounding Lug – Ground the generator to an approved earth ground here. See page 9 for details.

13)Idle Control Switch – The idle control runs the engine at normal (high) speeds when there is an electrical load present and runs the engine at idle (low) speeds when a load is not present.

Figure 6 - Engine Control Panel

1512

14

8

9

 

 

 

6

Page 8
Image 8
Generac 005308-0 Operation, Know The Generator, 1512, Generator Controls, Engine Control Panel, this generator