Genie CE, 82784, GS-2032, GS-2632 manual Electrocution Hazards

Models: GS-2632 GS-2032 82784 CE

1 34
Download 34 pages 55.39 Kb
Page 4
Image 4
Electrocution Hazards

Operator's Manual

Second Edition • Second Printing

 

 

 

 

 

 

SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance

 

Meters

 

 

0 to 300V

Avoid Contact

 

 

300V to 50KV

3.05

 

 

50KV to 200KV

4.60

 

 

200KV to 350KV

6.10

 

 

350KV to 500KV

7.62

 

 

500KV to 750KV

10.67

 

 

750KV to 1000KV

13.72

 

 

Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.