Second Edition • Second Printing | Operator's Manual | |
|
|
|
|
|
|
1Select a test area that is firm, level and free of obstruction.
2Be sure the battery pack is connected.
At the Ground Controls
3Pull out the platform and ground red Emergency Stop buttons to the on position.
4Turn the key switch to ground control.
5Observe the diagnostic LED readout.
Result: LED should read 23 or
Test Emergency Stop
6Push in the ground red Emergency Stop button to the off position.
Result: No functions should operate.
7Pull out the red Emergency Stop button to the on position.
Test the Up/Down Functions
The audible warnings on this machine and the standard horn all come from the same central alarm. The horn is a constant tone. The descent alarm sounds at 60 beeps per minute. The alarm that goes off when the pothole guards have not deployed sounds at 300 beeps per minute. The alarm that goes off when the machine is not level sounds at 600 beeps per minute. An optional
8 Activate the up function.
Result: The platform should raise.
9 Activate the down function.
Result: The platform should lower. The descent alarm should sound while the platform is lowering.
FUNCTION TESTS
Test Auxiliary Lowering/Manual Lowering
10 Activate the up function and raise the platform approximately 60 cm.
11Activate the auxiliary lowering/manual lowering function. Move the toggle switch OR pull the knob OR push the button.
Result: The platform should lower. The descent alarm will not sound.
12 Turn the key switch to platform control.
At the Platform Controls
Test Emergency Stop
13Push in the platform red Emergency Stop button to the off position.
Result: No functions should operate.
Test the Horn
14 Pull the red Emergency Stop button out to the on position.
15 Push the horn button.
Result: The horn should sound.