Genie TML-4000 Fall Hazards, Tip-over Hazards, Electrocution Hazards, Voltage, Minimum Safe, Feet

Models: TML-4000N TML-4000

1 28
Download 28 pages 12.98 Kb
Page 4
Image 4
Fall Hazards

Operator's Manual

Third Edition • Second Printing

 

 

 

 

 

 

SAFETY RULES

Fall Hazards

Do not stand on the machine.

Do not climb on the mast.

Tip-over

Hazards

Do not raise the mast to the vertical position unless all outriggers are properly deployed, the foot pads are in firm contact with the ground and the machine is level.

Do not set the machine up on a surface where it cannot be leveled using only the leveling jacks.

Do not hang any objects from the lights or mast.

Do not use the mast to raise material or personnel.

Do not move the machine unless the mast is lowered to the horizontal position and securely locked in place.

Do not extend the mast when wind speeds may exceed 60 mph / 27 m/sec.

Do not place ladders or scaffolds against any part of the machine.

Do not alter or disable machine components that in any way affect safety and stability.

Do not adjust or stow the outriggers when the mast is raised.

Do not use the machine on a moving or mobile surface or vehicle.

Be sure the tires are in good condition and the lug nuts are properly tightened.

Electrocution Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances away from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

 

Minimum Safe

Phase to Phase

Approach Distance

 

Feet

Meters

 

 

0 to 300V

Avoid Contact

 

 

 

300V to 50KV

10

3.05

 

 

 

50KV to 200KV

15

4.60

 

 

 

200KV to 350KV

20

6.10

 

 

 

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Allow for mast movement and electrical line sway or sag, and be aware of strong or gusty winds.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.

2

Genie TML-4000 andTML-4000N

Part No. 97600

Page 4
Image 4
Genie TML-4000 Fall Hazards, Tip-over Hazards, Electrocution Hazards, Voltage, Minimum Safe, Phase to Phase, Feet, Meters