Genie TMZ-50, TMZ-30 manual At the Ground Controls, Test Emergency Stop, Test Outrigger Interlock

Models: TMZ-17, TMZ-10 TMZ-50, TMZ-30

1 34
Download 34 pages 33.96 Kb
Page 20
Image 20
At the Ground Controls

Operator's Manual

First Edition • Third Printing

 

 

 

 

FUNCTION TESTS

7Check the interlock display. Be sure that all four interlock display lights are on.

8Start the engine (if equipped). See Operating Instructions section.

At the Ground Controls

Test Emergency Stop

9Push in the red Emergency Stop button to the OFF position.

Result: The engine (if equipped) should turn off. All ground and platform control functions should not operate.

10 Pull out the red Emergency Stop button to the ON position.

Test Outrigger Interlock

11 Start the engine (if equipped).

12 Push and hold an outrigger button and push and hold the retract outrigger button to raise one outrigger until the corresponding interlock display light turns off.

13 Activate the boom functions.

Result: Boom functions should not operate.

14 Push and hold the auto-level button. Push and hold the extend outrigger button. The outriggers will lower and adjust to level the machine and raise the wheels slightly off the ground.

15 Repeat the procedure for each outrigger.

Test the Boom Functions

16 Do not hold a function enable/speed select button. Attempt to activate each boom function button.

Result: All boom functions should not operate.

17 Press and hold a function enable/speed select button. Activate each boom function button.

Result: All boom functions should operate through a full cycle.

Test the Tilt Sensor

18 Raise the jib boom approximately 6 inches /

15 cm. Raise the primary boom approximately 6 inches / 15 cm off the boom rest. Raise the secondary boom approximately 6 inches /

15 cm off the boom rest. Extend the primary boom approximately 12 inches / 30 cm.

19 Locate the tilt sensor on the chassis near the ground controls.

20 Press down one side of the tilt sensor and place the tilt sensor test tool under one of the posts.

Result: The alarm, located in the platform, should sound after 1 second.

The interlock display light should flash.

21 Test all ground and platform control functions.

Result: The primary boom up, the secondary boom up, the jib boom up and the primary extend functions should not operate. The primary boom down, the secondary boom down, the jib boom down, the primary boom retract and the rotate functions should operate normally.

22 Remove the tilt sensor test tool.

18

Genie TMZ-50/30 & Genie TMZ-17/10

Part No. 72896

Page 20
Image 20
Genie TMZ-50, TMZ-30 manual At the Ground Controls, Test Emergency Stop, Test Outrigger Interlock, Test the Boom Functions