First Edition • Third Printing

Operator's Manual

 

 

 

 

Models with Engines - Manual Lowering

When the main power source fails (engine), the Battery Power light will come on and the machine is in auxiliary power mode.

The boom functions will operate at a reduced speed.

Auxiliary power mode is intended for short term use.

OPERATING INSTRUCTIONS

DC Models - Manual Lowering

All boom functions can be operated with the hand pump located under the function manifold side cover.

1 Select a function and it’s corresponding valve.

Primary boom retract function

1Push and rotate the valve spool. Operate the hand pump with a push/pull motion.

2Push and rotate the valve spool to return to normal operating mode.

Note: The valve spool must be reset for the boom extend function to operate.

All other functions

1Manually open the valve by pulling out or pushing in on the end of the valve spool.

2Hold the valve in the open position and operate the hand pump with a push/pull motion.

Function Manifold

Part No. 72896

Genie TMZ-50/30 & Genie TMZ-17/10

23

Page 25
Image 25
Genie TMZ-17, TMZ-10 manual Models with Engines Manual Lowering, DC Models Manual Lowering, Primary boom retract function