ROUTINE YEARLY
Lubricate the drive screw:
sWipe off old grease using a lint-free cloth.
sApply a light coating of silicon based grease (For best results, use Genie®
CORRECTIVE MAINTENANCE
CHANGE LIGHT BULBS
WARNING
sUse extreme caution when working from a ladder or step stool.
sWhen replacing light cover, make sure wires are not pinched or near moving parts.
1.Disconnect power to door opener. ss /PEN/Powerhead light cover.
ss2EMove light bulb(s).
ss2EPLAce light bulb(s).
–Do NOT use light bulbs with greater than 100 Watt rating.
ss#LOSE Powerhead light cover.
2.Reconnect power to door opener.
ssTest light operation.
RESET - OPEN/CLOSE TRAVEL LIMIT
Performing all ten (10) Limits/Force setting steps (page 5) erases previous Limits/Force settings.
NOTE: The opener will not close the door automatically unless the
DISENGAGING AND ENGAGING CARRIAGE
DISENGAGED
TO DISENGAGE, PULL DOWN ON THE RELEASE HANDLE AND LET GO.OPENER
ENGAGED
TO ENGAGE, PULL
DOWN AND TOWARD
THE OPENER. THEN LET GO.
REMOTE BATTERY REPLACEMENT
Replace remote battery with a CR 2032 coin cell battery.
1. Open the remote case using a washer or coin that fits into the slot at the top of the remote.
2. Replace battery.
3. Align components and snap case closed.
9 | ©2011 The Genie Company | 9/2011 |