14 Replacement of Parts

4078

CONTROL THERMOSTAT

SECURING SCREW (2)

 

 

RETAINING

 

 

PIN

 

 

OVERHEAT CUT

 

 

OFF PHIAL

 

ELECTRICAL

 

 

CONNECTION (5)

CONTROL

OVERHEAT

 

 

THERMOSTAT

CUT OFF

 

 

PHIAL

LOCKNUT

 

 

 

Diagram 14.4

CONTROLS

HIGH/LOW

CONTROL

4066

 

CONTROL

THERMOSTAT

FASCIA

KNOB

KNOB

 

 

 

SECURING

CONTROLS

SCREW (3)

FASCIA

 

Diagram 14.4A

 

4067S

ELECTRICAL

 

CONNECTIONS

 

RESET

FLUE HOOD

BUTTON

OVERHEAT

 

SECURING

THERMOSTAT

 

SCREW (2)

Diagram 14.5

14.5“High/Low” Control: diagram 14.4 and

Remove the fascia as described in Section 14.4. Remove the four screws securing the lights bracket. Remove the locknut to release the “High/Low” control. Disconnect the three in-line electrical connectors. When refitting refer to wiring diagram 13.2

14.6 Air Pressure Switch: diagram 14.7.

Remove the air pressure tubes and electrical connections.

Remove the two securing screws to release the air pressure switch.

When fitting the replacement make sure that all the air pressure tubes and electrical connections are made as shown.