Glowworm Lighting 40 manual General, Sheet Metal Parts Statutory Requirements, BSI Certification

Models: 40

1 40
Download 40 pages 37.42 Kb
Page 6
Image 6

1 General

119

640

460

360

50

65

710

25

 

FLUE

0156M

 

 

 

TERMINAL

 

 

DETAIL

 

 

102

 

 

124

 

 

63

 

42

Ensure flue slopes 2˚ down

 

towards the boiler

 

 

i.e. 35mm fall per metre

 

 

of flue length (2˚)

 

 

CONDENSATE DRAIN

 

 

WATER CONNECTIONS

 

 

GAS CONNECTION

 

32

70

300

 

 

DRAIN

CAPPED OFF

32

CONNECTION

 

Diagram 1.1

Important Notice

This boiler is for use only on G20 gas, but may be converted for use on G31 gas (L.P.G.) with an available conversion kit.

Energysaver 40, Kit No. 444708

The boiler is delivered in one pack.

Wherever possible, all materials and components to be used shall comply with the requirements of applicable British Standards.

BS5440 Part 1 and 2, BS5449, BS5546, BS6700, BS6798, BS6891 and BS7074 Part 1 and 2, BS7478, BS7593, BS7671.

We also suggest that you have to hand a copy of the British Gas publication, “Guidance Notes for the Installation of Domestic Condensing Boilers”.

Manufacturer’s notes must not be taken as overriding statutory obligations.

Where no British Standard exists, materials and equipment should be fit for their purpose and of suitable quality and workmanship.

This boiler must have fully pumped circuits, but is suitable for use with open vented or sealed water systems.

This boiler is not suitable for outdoor locations.

1.1 Sheet Metal Parts

WARNING. When installing or servicing the boiler care should be taken when handling sheet metal parts to avoid any possibility of personal injury.

1.2 Statutory Requirements

The installation of the boiler MUST be carried out by a competent person in accordance with the relevant requirements of the current issue of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations, The Building Regulations, The Building Standards (Scotland) Regulations (applicable in Scotland), local Water Company Bylaws, The Health and Safety at Work Act, Control of Substances Hazardous to Health, The Electricity at Work Regulations and any applicable local regulations.

Detailed recommendations are contained in the current issue of the following British Standards and Codes of Practice, BS4814,

BSI Certification

This boiler certificated to the current issue of P.A.S. 010 for performance and safety.

It is important that no alteration is made to the boiler, without permission, in writing, from Hepworth Heating Ltd.

Any alteration that is not approved by Hepworth Heating Ltd., could invalidate the warranty and could also infringe the current issue of the Statutory Requirements.

1.3 Range Rating

The boiler is range rated and is factory preset to maximum, but may be adjusted to suit individual system requirements, refer to Table 2.

1.4 General Data

The data label is positioned on the inner case, visible when the outer case is removed.

All dimensions on diagrams are given in millimetres (except as noted).

The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is 86.7%.

The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated have been certified by B.S.I.

221834B

6

Page 6
Image 6
Glowworm Lighting 40 manual Sheet Metal Parts Statutory Requirements, BSI Certification, Range Rating, General Data