2.3Contrast measurements

Use the Function button to select the function "EXPOSURE".

Keep the measuring key M pressed down and the meter will switch over to contrast measurement. Continue holding down the key to measure various other areas in the subject. In the display, the difference between the individual results of the additional measurements and the first measuring value will be indicated in EV. A new metering will be made approx.

2 times a second.

After you have released the measuring key M, the value of the first exposure measure- ment will reappear.

2.4Setting correction values In order to deliberately change the exposure of your photos, you may adjust the factory calibration.

– Remove the battery from the Digisix for a moment and then put it back again in the compartment. The meter will then make the self-test.

– During this test, keep the measuring key and also the function button pressed down until the accoustic signal sounds. Release the key to enter the CORRECTION function.

Use the measuring key M to enter or change the correction value.

Press the function button again to return the meter to the normal measuring functions.

GOSSEN Foto- und Lichtmeßtechnik

9

Page 9
Image 9
Gossen 15122 operating instructions Contrast measurements, Use the Function button to select the function Exposure