Spin Test

Setup

Electric Shock Hazard; page 6.

To check armature, motor winding and brush electrical continuity:

1. Relieve pressure; page 6.

2.Remove drive housing; page 24.

3.Fig. 7. Remove pressure control cover (39). Dis- connect red and black motor leads from control board.

4.Fig. 8. Remove motor shroud (74).

Armature Short Circuit Test

Quickly turn motor fan by hand. If no electrical shorts, motor coasts two or three revolutions before complete stop. If motor does not spin freely, armature is shorted. Replace motor; page 25.

Armature, Brushes, and Motor Wiring Open Circuit Test (Continuity)

1.Connect red and black motor leads together with test lead. Turn motor fan by hand at about two revolutions per second.

2.If uneven or no resistance, check for: broken brush springs, brush leads, motor leads; loose brush terminal screws, motor lead terminals; worn brushes. Repair as needed; page 12.

3.If still uneven or no resistance, replace motor; page 25.

39

F

G

 

9578A

Fig. 7

 

 

Motor Brush Replacement

Motor Brush Removal

Replace brushes worn to less than 1/4 in. (6 mm). Check both sides. See Parts List 309064 for correct brush kit for your series of sprayer.

1.Read General Repair Information; page 7.

2. Relieve pressure; page 6.

3.Fig. 8. Remove four screws (18) and motor shroud (74).

4.Pry off two brush caps (A). Tag locations of red (+) and black (--) motor leads. Cut tie wrap.

5.Fig. 5. Remove screw (C) and discard brush (B) for motor with capacitor attached. Remove brush leads from control box for motor without capacitor attached.

(Continued on page 13)