On/Off Switch Replacement

120 Vac

Removal

1. Relieve pressure; page 6.

2.Fig. 10 and 11. Remove four screws (18) and pressure control cover (39).

3.Disconnect two wires (A) from ON/OFF switch (23).

4.Remove toggle boot (25) and locking ring (24). Remove ON/OFF switch (23).

Installation

1.Install new ON/OFF switch (23). Install locking ring (24) and toggle boot (25).

2.Connect two wires (A) to ON/OFF switch.

3.Install pressure control cover (39) with four screws (18).

25

24

 

35

37

 

A

 

23

36

 

 

 

18

 

 

22

D E

52

39

ti0057b

Fig. 10

14309063