Grounding and Electric Requirements

WARNING

Your system must be grounded. Read warnings, page 3.

The sprayer cord includes: a grounding wire with an

appropriate grounding contact.

 

ti7480a

Fig. 3

 

The sprayer requires:

110--120V units: 100--130 VAC, 50/60 Hz, 15A, 1 phase, circuit with a grounding receptacle.

240V Units: 210--255 VAC, 50/60 Hz, 7.5A, 1 phase, circuit with a grounding receptacle.

Never use an outlet that is not grounded or an adapter.

 

ti7482a

Fig. 5

 

Recommended extension cords for use with this sprayer:

D110--120V: 3--wire, 12 AWG (2.5 mm2) minimum, 300 ft. (90 m) maximum length.

D240V: 3--wire, 16 AWG (1.0 mm2) minimum, 300 ft. (90 m) maximum length.

Smaller gauge or longer extension cords may reduce sprayer performance.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Solvent and Oil--based fluids: follow local code. Use only conductive metal pails placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

ti7481a

 

 

Fig. 4

 

 

Do not use the sprayer if the electrical cord has a

 

 

damaged ground contact. Only use an extension cord

Fig. 6

ti7483a

with an undamaged ground contact.

 

8309063

Page 8
Image 8
Graco 309063F Grounding and Electric Requirements, Sprayer cord includes a grounding wire with an, Sprayer requires