![Connecting the Control Assembly to a Power Source](/images/new-backgrounds/65124/6512427x1.webp)
Installation
Connecting the Control Assembly to a Power Source
Perform the following procedure to connect the control assembly to a power source.
ELECTRIC SHOCK HAZARD
Do not connect the PrecisionSwirl control assembly to a power source unless you are a trained electrician. Failure to follow standard procedures or to observe the necessary precautions could result in serious bodily injury or equipment damage.
CAUTION
If power and grounding connections are not done properly, the equipment may be damaged and the warranty will be voided.
Have a qualified electrician connect the PrecisionSwirl control assembly to a grounded electrical source that has the following required service ratings:
Description | Requirements |
|
|
Vac | |
|
|
Hz | 50/60 |
|
|
Phase | 1 |
|
|
Full Load Amps | 0.42 at 120 Vac |
|
|
Circuit Breaker | 5 Amp |
|
|
Power to the control assembly must be supplied from a source with a
To connect the control assembly to the electrical source:
1.Shut off system power at the main circuit breaker.
2.Locate the opening on the bottom of the control assembly, labeled POWER SUPPLY. See FIG. 6.
0/7%2 | ||
3500,9 | #!",% | #!",% |
8027A
7/8 in. Diameter power supply entry
FIG. 6
3.Using 16 AWG wire or larger, connect electrical power to L1 (hot), L2 (neutral) power terminals in the PrecisionSwirl control assembly. See FIG. 8.
4.Use a cord grip to seal the area where wires enter the control assembly.
Any fitting that is used to connect a power cord (or conduit for power wiring) to the control assembly must provide a
5.Apply system power at the main circuit breaker.
6.Move the POWER switch to the ON position, apply- ing power to the control assembly.
14 | 310554V |