Graco 310554V Connecting the Control Assembly to a Power Source, Electric Shock Hazard

Models: 310554V

1 46
Download 46 pages 58.19 Kb
Page 14
Image 14
Connecting the Control Assembly to a Power Source

Installation

Connecting the Control Assembly to a Power Source

Perform the following procedure to connect the control assembly to a power source.

ELECTRIC SHOCK HAZARD

Do not connect the PrecisionSwirl control assembly to a power source unless you are a trained electrician. Failure to follow standard procedures or to observe the necessary precautions could result in serious bodily injury or equipment damage.

CAUTION

If power and grounding connections are not done properly, the equipment may be damaged and the warranty will be voided.

Have a qualified electrician connect the PrecisionSwirl control assembly to a grounded electrical source that has the following required service ratings:

Description

Requirements

 

 

Vac

100-240

 

 

Hz

50/60

 

 

Phase

1

 

 

Full Load Amps

0.42 at 120 Vac

 

 

Circuit Breaker

5 Amp

 

 

Power to the control assembly must be supplied ELECTRIC SHOCK HAZARDDescription from a source with a lockable–off disconnect switch, or by use of a cord with a plug–and–socket connection to the source of power.

To connect the control assembly to the electrical source:

1.Shut off system power at the main circuit breaker.

2.Locate the opening on the bottom of the control assembly, labeled POWER SUPPLY. See FIG. 6.

0/7%2

!54/-!4)#)#/.42/,

-/4/2

3500,9

#!",%

#!",%

8027A

7/8 in. Diameter power supply entry

FIG. 6

3.Using 16 AWG wire or larger, connect electrical power to L1 (hot), L2 (neutral) power terminals in the PrecisionSwirl control assembly. See FIG. 8.

4.Use a cord grip to seal the area where wires enter the control assembly.

Any fitting that is used to connect a power cord (or RequirementsManual background conduit for power wiring) to the control assembly must provide a liquid–tight seal.

5.Apply system power at the main circuit breaker.

6.Move the POWER switch to the ON position, apply- ing power to the control assembly.

14

310554V

Page 14
Image 14