Graco 310554V important safety instructions Troubleshooting, Problem, Cause, Solution

Models: 310554V

1 46
Download 46 pages 58.19 Kb
Page 25
Image 25
Troubleshooting

Troubleshooting

Troubleshooting

Some solutions require disassembling the dispense valve or orbital dispenser. Always relieve system pressure before performing these procedures.

Table 3 provides troubleshooting information. For other troubleshooting situations, call your Graco distributor.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pres- sure Relief Procedure (see manual 309043).

To reduce the risk of serious injury whenever you are instructed to remove, change, check, clean, or han- dle the nozzle in any manner, always disconnect the motor control cable from the control assembly (see FIG. 8 on page 17), or place the control assembly in the MANUAL mode of operation using the CON- TROL SELECT switch. (See FIG. 12 on page 22.)

Table 3. Troubleshooting

Problem

Cause

Solution

 

 

 

 

 

 

No material being dispensed

Clogged nozzle

Change nozzle.

 

 

 

 

No material or pressure

Check fluid delivery system.

 

 

 

 

Broken or clogged dispense tube

Rebuild the orbital dispenser.

 

 

 

 

Fault in dispense valve

Refer to Dispense Valve manuals

 

 

308876 or 309376.

 

 

 

Material dispensing but not swirling

Motor not operating

Check wiring connections and cable.

(Motor fault light is on)

 

 

 

Tube bearing defective; replace tube

 

 

 

 

bearing.

 

 

 

 

 

Motor defective; replace motor.

 

 

 

 

 

Check for fluid leak.

 

 

 

 

Control assembly failure

Check analog voltage control setting

 

 

and enable signal.

 

 

 

 

 

Check RPM setting.

 

 

 

 

 

Check power and fuses.

 

 

 

 

 

Check wiring.

 

 

 

 

Orbiter bearing failure

Replace bearing.

 

 

 

Material dispensing but not swirling

Material accumulating on nozzle

Clean nozzle.

(Motor fault light is off)

 

 

 

 

 

Motor is rotating but poor swirl pat-

Flow rate has changed

Check flow rate.

tern or change in bead size

 

 

Motor speed has changed

Check analog speed signal.

 

 

 

 

 

Material viscosity has changed

Check material parameters.

 

 

 

 

Partially clogged nozzle

Clean nozzle.

 

 

 

310554V

25

Page 25
Image 25