Graco 310692D Operation, Pressure Relief Procedure, Applying the Fluid, Incorrect, Correct

Models: 310692D

1 34
Download 34 pages 62.93 Kb
Page 13
Image 13
Operation

Operation

Operation

Pressure Relief Procedure

WARNING

Follow Pressure Relief Procedure, page 13 when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings, page 3.

1.Turn off air and fluid supply.

2.Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure.

1.To achieve the best results when applying fluid:

Keep the gun perpendicular and 6 to 8 inches (150 to 200 mm) from the object being sprayed.

Use smooth, parallel strokes across the surface to be sprayed with 50% overlap.

Incorrect

ti4843a

Correct

ti4836a

FIG. 11

Applying the Fluid

When using the HVLP spray gun, instead of a conven- tional airspray gun, you may need to use a slightly slower hand movement and make fewer passes with the gun to coat a part. This is due to the reduced spray velocity produced by lower HVLP air pressures, along with a larger fluid particle size because there is less air to blow off solvents than what is produced by conven- tional airspray. Take care to avoid runs or sags as you spray.

ti4842a

FIG. 12

310692D

13

Page 13
Image 13
Graco 310692D important safety instructions Operation, Pressure Relief Procedure, Applying the Fluid, Incorrect, Correct