Troubleshooting

Troubleshooting

WARNING

Follow Pressure Relief Procedure, page 13 when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings, page 3.

Problem

 

Cause

 

Solution

 

 

 

 

 

 

 

 

 

 

Fluid flow is fluttering while spraying.

1.

Fluid nozzle not tight enough.

1.

Tighten fluid nozzle to 40 in-lb

 

2.

Fluid filter clogged.

 

(4.5 N•m).

 

 

 

 

3.

Fluid source empty.

2.

Check fluid filter.

 

 

 

 

 

 

3.

Refill

 

 

 

 

 

Fluid flow fades while spraying high

1.

Air hose size is too restricted for

1.

Use 5/16 in. (7.9 mm) I.D. air

viscosity fluids.

 

higher air flow being used.

 

hose if the hose is 25 ft. (7.6 m)

 

 

 

 

long. If longer hose is needed,

 

 

 

 

use a 3/8 in. (9.5 mm) I.D. hose.

 

 

 

 

 

Pattern becomes off-set or heavy on

1.

Air cap horn holes plugged or

1.

Clean air cap horn holes with

ends.

 

damaged.

 

non-metallic item such as a

 

2.

Nozzle tip dirty or damaged.

 

toothpick, or replace air cap.

 

 

 

 

 

 

2.

Clean or replace nozzle.

 

 

 

Gun fluid pressure is too high with

Using needle/nozzle kit with too small

Use needle/nozzle kit with larger ori-

gun triggered (cannot achieve

orifice.

fice.

desired flow rate).

 

 

 

 

 

 

 

Using a low fluid pressure setting, the

Using needle/nozzle kit with too large

Use needle/nozzle kit with smaller

fluid flow is too high, making it neces-

orifice.

orifice.

sary to restrict needle travel to

 

 

 

 

reduce fluid flow.

 

 

 

 

 

 

 

Fluid system will not operate at low

There is no fluid regulator, or air reg-

Add low pressure fluid regulator, or

enough fluid pressure [below 10 psi

ulator or pressure pot is not sensitive

add more sensitive low pressure air

(70 kPa, 0.7 bar)].

enough at low pressures.

regulator on pressure pot.

 

 

 

 

 