Technical Data

Technical Data

 

MAGNUM X5 (Series D)

MAGNUM X7 (Series C)

 

 

 

Working pressure range

0-3000 psi (0-21 MPa, 0-207 bar)

0-3000 psi (0-21 MPa, 0-207 bar)

 

 

 

Electric motor

9.0A (open frame, universal)

9.0A (open frame, universal)

 

 

 

Operating horsepower

1/2

5/8

 

 

 

Maximum delivery (with tip)

0.27 gpm (1.02 lpm)

0.31 gpm (1.17 lpm)

 

 

 

Paint hose

1/4 in. x 25 ft (6.4 mm x 7.5 m)

1/4 in. x 25 ft (6.4 mm x 7.5 m)

 

 

 

Maximum tip hole size

0.015 in. (0.38 mm)

0.017 in. (0.43 mm)

 

 

 

Weight, sprayer only

13.3 lb (6.0 kg)

23.3 lb (10.6 kg)

 

 

 

Weight, sprayer, hose & gun

16.5 lb (7.5 kg)

26.5 lb (12.0 kg)

 

 

 

Dimensions (Upright):

 

 

 

 

 

Length

14.5 in. (36.8 cm)

19.3 in. (49.0 cm)

 

 

 

Width

12.4 in. (31.5 cm)

15.3 in. (38.9 cm)

 

 

 

Height

17.9 in. (45.5 cm)

37.0 in. (94.0 cm)

 

 

 

Dimensions (Folded):

 

 

 

 

 

Length

N/A

19.3 in. (49.0 cm)

 

 

 

Width

N/A

15.3 in. (38.9 cm)

 

 

 

Height

N/A

29.2 in. (74.2 cm)

 

 

 

Power cord

18 AWG, 3-wire, 6 ft (1.8 m)

 

 

Fluid inlet fitting

3/4 in. internal thread (standard garden hose thread)

 

 

Fluid outlet fitting

1/4 NPSM external thread

 

 

Inlet screen (on suction tube)

35 mesh (450 micron)

 

 

Wetted parts, pump & hose

stainless steel, brass, leather, ultra-high molecular weight polyethylene

 

(UHMWPE), carbide, nylon, aluminum, PVC, polypropylene, fluroelastomer

 

 

Wetted parts, gun

aluminum, brass, carbide, nylon, plated steel, stainless steel, UHMWPE, zinc

 

 

Generator requirement

1500 Watt minimum

 

 

Electrical power requirement

120 Vac, 60 Hz, 15A, 1 phase

 

 

Storage temperature range ◆❖

-30° to 160°F (-35° to 71°C)

 

 

Operating temperature range

40° to 115°F (4° to 46°C)

 

 

 

When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in

pump.

Damage to plastic parts may result if impact occurs in low temperature conditions.

Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.